Installation requirements
Ins
tallation r
equir
ement
s
This range is designed to operate at a
pressure of 5 in (13 cm) of water column on
natural gas or 10 in (25 cm) of water column
on LP gas (propane or butane).
Make sure you are supplying your range
with the type of gas for which it is designed.
Do not attempt to convert the appliance
from the gas specified in this manual to a
different gas without consulting the gas
supplier.
This range is convertible for use on natural
or propane gas. If you decide to use this
range on LP gas, conversion must be made
by a qualified LP installer before attempting
to operate the range.
For proper operation, the pressure of natural
gas supplied to the regulator must be
between 5 in and 13 in (13 cm and 33 cm)
of water column.
For LP gas, the pressure supplied must be
between 10 in and 13 in (25 cm and 33 cm)
of water column.
When checking for proper operation of the
regulator, the inlet pressure must be at least
1 in (2.5 cm) greater than the operating
(manifold) pressure as given.
The pressure regulator located at the inlet
of the range manifold must remain in the
supply line regardless of whether natural or
LP gas is being used.
A flexible-metal appliance connector used
to connect the range to the gas supply
line should have an I.D. of 0.5 in (1.3 cm)
and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors
must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal
tubing when moving the range.
Gas requirements
Provide adequate gas supply
Содержание NY58J9850WS
Страница 1: ...Dual Fuel Range Installation manual NY58J9850WS ...
Страница 46: ...Memo ...
Страница 47: ...Memo ...
Страница 49: ...Estufa de combustible dual Manual de instalación NY58J9850WS ...
Страница 94: ...Notas ...
Страница 95: ...Notas ...
Страница 97: ...Cuisinière mixte Manuel d installation NY58J9850WS ...
Страница 142: ...Notes ...
Страница 143: ...Notes ...