82
Ⅲ. ADJUSTMENT
12. Slide Button Adjustment
A. Purpose
Even if a slide button has passed individual part inspection, the slide button may not work during the finished
product inspection due to various environmental factors.
Hence it is inefficient to classify the finished product as defective just because of a defective slide button.
In particular, when the defect is caused by setting the slide button recognition threshold too low, the problem
can be resolved by changing the setting. The following shows how to change the setting to resolve the
problem.
B. Procedures
①
Copy the adjust12.txt and adjust_t files onto the root directory of the SD card and install the card into the
camera.