13
3. Disassembly and Reassembly
3-3 Removing Touch PCB
WARNING
Disconnect power before servicing the range Replace all panels before operating range. Failure to do so
can result in death or electrical shock.
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts. Sharp edges may
be present, and you can cut yourself if you are not careful.
Parts
Explanation Photo
Explanation
Touch PCB
1.
Turn off the electrical supply going
to the range.
2.
Pull the range away from the wall
so that you can access the rear
panel.
3.
Remove Cover-Back Guard Wire
(See step 4 on page 11)
4.
Remove Touch PCB connectors
which be replaced.
5.
Remove 2 screws.(Right Touch
PCB) or Remove 3 screws.
(Left Touch PCB).
6.
Replace Touch PCB.
* Reassembly of All part is the reverse order of disassembly.