38
Field setting mode
English
Fiel
d S
etting Mode
Mixing vavle Installation (Field Option)
࡙
The FSV #4041 should be set to “1 or 2” to use mixing valve.
࢘ߥߡߥߢॉߢࡠAͱ͝ϩθͱ̷̷ʪʒɵɇϑʪʒͱ͝ϩ˵ʪϩʪ͔ΧʪθɇϩЇθʪʒ̈˙˙ʪθʪ͝ʀʪ࣍ߥߡߥߣࡡߥߡߥߤ࣎
࢘ߥߡߥߢॉߣࡠAͱ͝ϩθͱ̷̷ʪʒɵɇϑʪʒͱ͝ϩ˵ʪϩʪ͔ΧʪθɇϩЇθʪʒ̈˙˙ʪθʪ͝ʀʪͱ˙ϩ˵ʪǮøЭɇ̷Їʪ
ex) Heating
<#4041=1>
<#4041=2>
Tw2
FCU WL
Floor temp
Ta
#4042
Tw2
FCU WL
Floor WL
Ta
࡙
FSV #4042 / #4043 is for adjusting temperature difference between Tw3 (Tw2) and Tw4.
࡙
When using mixing valve, FSV #4046 should be matched with mixing valve running time charateristic.
Inverter Pump Installation (Field Option)
࡙
FSV #4051=1 (Default) : Inverter pump use + Output 100%, FSV #4051=2 : Inverter pump use + Output
70%, FSV #4051=0 : Inverter pump Not use.
࡙
FSV #4052 is for adjusting temperature difference between Tw2 and Tw1.
NOTE
࡙
Tw1 (Inlet Water Temp), Tw2 (Discharge Water Temp), Tw3 (Backup Heater oulet Water Temp),
Tw4 (Mixing valve Temp.)
Zone Control (Field Option)
࡙
Zone control Using Wired Remote Control (install option) FSV # 4061 should be set to "1 (Yes)" to zone
control.
ࣕ
To use the zone control (FSV #4016=1), set the thermostat control option (FSV #2091 & #2092) to "0"
for disabling it.
ࣕ
This field option controls each zone (Zone 1, Zone 2) with a wired remote controller setting not by
using the external room thermostat signal.
NOTE
࡙
MIM-E03CN (MONO Control Kit) model does not support this zone control function.