30
Field setting mode
English
Fiel
d S
etting Mode
Field Setting Value (FSV) 30**
Code 30** : User’s options for Domestic Hot Water(DHW) tank heating
࡙
The values in the following table are just examples for your understanding.
Main Menu &
Code
Menu
Function
Sub
Code
MODEL CODE :
AE200(260)RNW***
MODEL CODE :
MIM-E03CN
Setting Standard
Setting Standard
Item
Step Unit
Default Min. Max.
Default
Min. Max.
Domestic
Hot Water
Tank
Code 30**
DHW
DHW mode
activate
DHW mode
-
-
3011
1
0
2
0
0
2
Heat Pump
Max. Temp.
1
ઑA
3021
55
45
55
55
45
55
Stop
1
ઑA
3022
0
0
10
2
0
10
Start
1
ઑA
3023
5
5
30
5
5
30
Min. Operating
Time
1
min 3024
5
1
20
5
1
20
Max. Operating
Time
5
min 3025
30
5
95
30
5
95
Operation
Interval
0.5 hour 3026
3
0.5
10
3
0.5
10
Booster
Heater
On/Off
-
-
3031 1 (On) 0 (Off)
1
1 (On)
0 (Off)
1
Delay Time
5
min 3032
20
20
95
20
20
95
Overshoot
1
ઑA
3033
0
0
4
0
0
4
Disinfection
On/Off
-
-
3041 1 (On) 0 (Off)
1
1 (On)
0 (Off)
1
Interval
1
day 3042 Fri (5) Sun (0) All (7)
Fri (5)
Sun (0) All (7)
Start Time
1 o'clock 3043
23
0
23
23
0
23
Target Temp.
5
ઑA
3044
70
40
70
70
40
70
Duration
5
min 3045
10
5
60
10
5
60
Max time
1
hour 3046
ߩ
1
24
ߩ
1
24
Forced DHW
Operation
Timer OFF
Function
-
-
3051 0 (No)
0
1 (Yes)
0 (No)
0
1 (Yes)
Time Duration
1
(x10)
min 3052
6
3
30
6
3
30
Solar Panel/
DHW
Thermostat
H/P
Combination
1
-
3061 0 (No)
0
2
0 (No)
0
2
3-way Valve Defalut Direction -
-
3071 0 (Room)
0
1 (Tank) 0 (Room)
0
1 (Tank)