4. Troubleshooting
► Error Code
A1–2111
A1–2113
► Error message
Motor Failure: #A1-2111. Turn off then on. Call for service if the problem persists.
Motor Failure: #A1-2113. Turn off then on. Call for service if the problem persists.
► Symptom
OPC motor does not operate. / OPC motor is operational but machine recognizes status as stopped.
► Troubleshooting method
1) Turn the machine off then on. If the error persists, turn the machine off again.
2) Open the side cover. Check if there are any foreign substances or paper around drum drive unit.
(Refer to 3.3.20. Side unit)
3) Remove the rear cover
(Refer to 3.3.2. Rear cover)
4) Check if the OPC motor connector is connected correctly.
5) If the connection is OK, turn the machine on. Enter the SVC mode. Select the yellow OPC motor test.
(Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0044)
a)
If the motor does not operates,
Copyright© 1995-2017 SAMSUNG. All rights reserved.
4-70
Содержание MultiXpress K4 Series
Страница 10: ...Contents 6 4 Document Revision List 6 10 ix Copyright 1995 2017 SAMSUNG All rights reserved ...
Страница 53: ...2 Product Specifications and Description Copyright 1995 2017 SAMSUNG All rights reserved 2 37 ...
Страница 76: ...2 Product Specifications and Description 2 60 Copyright 1995 2017 SAMSUNG All rights reserved ...
Страница 139: ...3 Disassembly and Reassembly 7 Release the reverse roller Assy Copyright 1995 2017 SAMSUNG All rights reserved 3 18 ...
Страница 177: ...3 Disassembly and Reassembly 7 Remove the scan glass Copyright 1995 2017 SAMSUNG All rights reserved 3 56 ...
Страница 432: ...4 Troubleshooting Step Check item Action Refer to 3 3 29 4 197 Copyright 1995 2017 SAMSUNG All rights reserved ...