Samsung Electronics
92
Troubleshooting
The error indicated on the PCB display of outdoor unit(cont.)
Outdoor unit EEV open error (self diagnosis)
EEV
Outdoor unit EEV close error (self diagnosis)
EEV
High temperature (over 30˚C) of outdoor as heating mode
Operation mode
Low temperature (under -5˚C) of indoor as cooling mode
Operation mode
wrong connection between communication and power cable
Wiring indoor and outdoor
Inverter compressor starting failure (5 times)
Compressor trip by input current limit control
Compressor trip by OLP temperature limit control
Compressor peak current protection
Compressor overload protection by current
DC-link voltage error (under 150V or over 410V)
Compressor rotation error
Current sensor error
DC-link voltage sensor error
Compressor overload protection
EEPROM error
AC line zero-crossing detection circuit error
NO GAS error (self diagnosis)
Main checking Point
Display
Explanation
DB98_20402A(1)_2 10/26/04 3:27 PM Page 92
Содержание MH052FDEA
Страница 106: ...MEMO 105 Samsung Electronics ...
Страница 113: ...Samsung Electronics 112 Exploded Views and Parts List 1 2 8 9 10 11 3 6 7 4 5 ...
Страница 132: ...131 Samsung Electronics 11 PCB Diagram 11 1 MAIN PCB Indoor Unit TOP ...
Страница 133: ...Samsung Electronics 132 PCB Diagram BOTTOM ...
Страница 136: ...135 Samsung Electronics 11 2 MAIN PCB Outdoor Unit 11 2 1 MH068FXEA4 MH080FXEA4 TOP ...
Страница 137: ...Samsung Electronics 136 PCB Diagram BOTTOM ...
Страница 154: ...153 Samsung Electronics MH052FPEA Schematic Diagram This Document can not be used without Samsung s authorization ...
Страница 156: ...155 Samsung Electronics Schematic Diagram This Document can not be used without Samsung s authorization MH052FDEA ...