6-1-9 Low Temp. Release
●
AT COOLING MODE
◆
If the temperature of indoor heat exchanger is below -1°C for over 6minutes, the outdoor fan turns off.
◆
If the temperature of indoor heat exchanger increase over 5°C during the first protection function, the first freezing protection
function is released and the outdoor fan turns on.
◆
If the temperature of indoor heat exchanger increase over 0°C during 6 minutes counting, 6 minutes counter is cleared.
◆
If the temperature of indoor heat exchanger maintains for a minute at -4°C during the 6 minutes counting, switch off the
compressor.
◆
If the compressor is off by Low Temp. Release, 5 minutes release is impossible.
◆
Operation pattern
Indoor Heat exchanger Temp.(˚C)
5[˚C]
0[˚C]
-1[˚C]
6min 6min 6min
COUNT
ON
Low temp.
release
ON
Low temp.
release
OFF
6min
3sec
2sec
ON
ON
OFF
ON
ON
OFF
Setting Fan speed
Setting Fan speed
"LL"
COMP_or
Outdoor FAN
Indoor FAN
*LL = Low FAN speed – 35rpm
COUNT
ON
COUNT
ON
DB98_20402A(1)_1 10/26/04 2:58 PM Page 80
Содержание MH052FDEA
Страница 106: ...MEMO 105 Samsung Electronics ...
Страница 113: ...Samsung Electronics 112 Exploded Views and Parts List 1 2 8 9 10 11 3 6 7 4 5 ...
Страница 132: ...131 Samsung Electronics 11 PCB Diagram 11 1 MAIN PCB Indoor Unit TOP ...
Страница 133: ...Samsung Electronics 132 PCB Diagram BOTTOM ...
Страница 136: ...135 Samsung Electronics 11 2 MAIN PCB Outdoor Unit 11 2 1 MH068FXEA4 MH080FXEA4 TOP ...
Страница 137: ...Samsung Electronics 136 PCB Diagram BOTTOM ...
Страница 154: ...153 Samsung Electronics MH052FPEA Schematic Diagram This Document can not be used without Samsung s authorization ...
Страница 156: ...155 Samsung Electronics Schematic Diagram This Document can not be used without Samsung s authorization MH052FDEA ...