E-
7
ENGLISH
C
OMPLETING THE
I
NSTALLATION
Deciding on where to install the Air Conditioner
MH050FXEA2B
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
026/035
MH050FXEA2B
1,220-240, 50
Unit
Outside diameter
Liquid
Gas
026/035
1/4"
3/8"
MH050FXEA2B outdoor unit cannot be connected to the following indoor unit combination.
-MH052FMEA/MH052FUEA/MH052FEEA
Piping outside diameter
(h)
(H)
A
B
600 mm
minimum
1 Room max
length
2 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
20m
30 m
15m
7.5 m
Composition
A,B
A+B
(H)
(h)
Piping length and the height
Main power switch
300 mm
minimum
300 mm
minimum
600 mm
minimum
CAUTION:
3 m as minimum pipe length: It will reduce
noise and vibration.
This value must be increased at 7.5 meters
in case it is connected just one indoor unit.
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
Make at least one round:
It will reduce noise and vibration
Содержание MH050FXEA2B
Страница 32: ......