7-4 Easy Sensor Calibration Check
Samsung Electronics
Troubleshooting
Step Activities
1 Put Inspection - 200cc A cup of w ater on the Tray center.
* If Display show s "FFFF",
Then;
-. Leave unit in room temperature abut 20 minutes for cooling.
-. Calibrate Easy Sensor from the beginning step of calibration method.
-. Check Easy Sensor Voltage again.
for 2 seconds.
2 Press Auto Easy Sensor Defrost & Clock Button
3 Check calibration result(Hexadecimal)
7-5 How to replace Sensor PCB
Step Activities
1 Remove 5 screw s, and disconnect outer panel.
(
Note
: You have to use screw driver w ith less than 05 and 10cm or more. )
2 Remove 1 screw for fastening of cover blow er, and disconnect cover blow er.
3 Remove screw s for fastening of sensor PCB through opening in the back, and disconnect sensor PCB.
5
(STEP 1)
Connect w ires correctly and exactly after replacing sensor PCB, and assemble sensor PCB in reverse order of
disassembling.
Note :
After reolacing M GT,assembly, PCB and sensor PCB, make ues of them after calibrating them all the time by using calibration jig.
(For more details, see contents of 7,7-1,7-2, 7-3 and 7-4 of previous page.)
4 Disconnect all of lead w ires from sensor PCB.
Calibration Check Button
(STEP 2)
(STEP 4)
(
STEP 3)
Cover Blower
Sensor PCB
Screwdriver
Содержание M1777
Страница 24: ...9 P C B Diagrams 9 1 P C B Diagrams Samsung Electronics 9 1...
Страница 27: ...ELECTRONICS Samsung Electronics Co Ltd May 2000 Printed in Korea DE68 01203A...
Страница 51: ...9 P C B Diagrams 9 1 P C B Diagrams Samsung Electronics 9 1...
Страница 54: ...ELECTRONICS Samsung Electronics Co Ltd May 2000 Printed in Korea DE68 01203A...