![Bakers Pride Cyclone CO11-E1 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/bakers-pride/cyclone-co11-e1/cyclone-co11-e1_instruction-sheet_3527781001.webp)
INSTRUCTIONS TO REPLACE
INVENSYS TEMPERATURE
CONTROL WITH FAST G6
TEMPERATURE CONTROL ON
COCE/CO11E OVENS
30 Pine Street • New Rochelle • New York • 10801
1 - 914 / 576 - 0200
1 - 914 / 576 - 0605
1 - 800 - 431 - 2745
www.bakerspride.com
fax
US & Canada
web address
BAKERS
PRIDE
!
!
WARNING: Shut off the power to the oven, use lock-out, tag-out. Do not
attempt to perform this service unless the oven has been disconnected
from the power source. Injury or death may occur if the power remains
connected.
1
U4132A
Instruction sheet
1
U4203QA
Wire diagram
1
N/A
¼” Drill bit
1
M0110A
Thermostat, G6, F.A.S.T.
1
M1555A
RTD temperature probe
1
Q4021A
Clip for RTD probe
2
Q1407A
#10 X ½” hex, slotted screw
2
Q1001A
6-32 X ¼” slotted screw
2
Q3058A
#6 internal tooth washer
2
P1085A
¼” X .032 fast on female connector with insulated shank
3
P1116A
Terminal, twin adapter
6
P1106A
Cable tie
1
U1428A
Temperature overlay
1
N/A
Jumper wire
This Field Retrofit Kit contains the following:
QUANTITY PART NUMBER DESCRIPTION
1)
Remove the side access cover screws and cover and put aside.
2)
Remove the front control panel as follows:
A) Remove the two upper and two lower screws and put aside.
B) Pull the knob located at the top of the control panel to remove the panel.
3)
Remove the temperature probe from the inside of the oven. Put the screws aside.
4)
Use the ¼” drill bit (provided) to enlarge the hole where the old probe was removed
.
Do not enlarge the holes that the probe brackets were removed from.
5)
Insert the new RTD probe (provided) by passing the wires from the inside of the oven
through the hole that was just enlarged, to the control panel area. Use the new probe
bracket (provided) and place it over the probe. Position the probe and bracket so the hole
in the bracket is lined up with the hole the previous probe bracket was fastened to. Install
the screw previously removed to hold the probe and bracket in place. Insert the other
screw previously removed to fill the hole that is no longer used. (new screws are provided in
the kit, if needed)
P/N U4132A 9-07
1