Samsung Electronics 5-3
3. After moving the water into another glass vessel, place it in the center of the cooking tray. Set the oven to high
5. Subtract T2 from T1. This will give you the water temperature rise. ( T)
6. The output power is obtained by the following formula;
7. Normal temperature rise for this model is 9 C to 11 C at 'HIGH'.
NOTE 1: Variations or errors in the test procedure will cause a variance in the temperature rise.
Additional power test should be made if temperature rise is marginal.
NOTE 2: Output power in watts is computed by multiplying the temperature rise (step E) by a factor of 91
times the of centigrade temperature.
The microwave heat distribution can be checked indirectly by measuring the water temperature rise at
certain positions in the oven:
1. Prepare five beakers made of 'Pyrex', having 100 milliliters capacity each.
2. Measure exactly 100milliliters off water load with a measuring cylinder, and pour into each beaker.
3. Measure the temperature of each water load. (Readings shall be taken to the first place of decimals.)
4. Put each beaker in place on the cooking tray as illustrated in figure below. Start heating.
5. After heating for 2 minutes, measure the water temperature in each beaker.
6. Microwave heat distribution rate can be calculated as follows:
Minimum
Temperature Rise
Heat Distribution = X 100(%)
Maximum
Temperature Rise
The result should exceed 65%.
Output Power =
49
49 : Counting Time (sec)
52 : Heating Time (sec)
4.187 : Coefficient for Water
1000 : Water (cc)
T : Temperature Rise (T1-T2)
To : Room Temperature
Wb : Beaker Weight
5-9 M icrow ave Heat Distribution - Heat Evenness
Alignment and Adjustments
.
power and operate for 52 seconds exactly. (3 seconds included as a holding time of magnetron oscillation:)
4. When heating is finished, stir the water again with the thermometer and measure the temperature ("T2").
Alignment and Adjustments
.
Alignment and Adjustments
The output power of the magnetron can be measured by performing a water temperature rise test.
Equipment needed :
* Two 1-liter cylindrical borosilicate glass vessel (Outside diameter 190 mm)
* One glass thermometer with mercury column
NOTE: Check line voltage under load. Low voltage will lower the magnetron output. Make all temperature
and time tests with accurate equipment.
1. Fill the one liter glass vessel with water.
2. Stir water in glass vessel with thermometer, and record glass vessel's temperatur ("T1",10
1 C)
.
4.187x1000x T+0.55xWbx(T
0
-T
2
)
5-8 Output Pow er of M agnetron
Alignment and Adjustments
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
D
D
D/ 4
D/ 4
D/ 4
D/ 4
Cooking Tray
Beaker
CAUTION
M ICROW AVE RADIATION
PERSONNEL SHOULD NOT ALLOW EXPOSURE TO M ICROWAVE RADIATION FROM M ICROWAVE GENERATOR OR OTHER PARTS
CONDUCTING M ICROWAVE ENERGY.
Содержание M1777
Страница 24: ...9 P C B Diagrams 9 1 P C B Diagrams Samsung Electronics 9 1...
Страница 27: ...ELECTRONICS Samsung Electronics Co Ltd May 2000 Printed in Korea DE68 01203A...
Страница 51: ...9 P C B Diagrams 9 1 P C B Diagrams Samsung Electronics 9 1...
Страница 54: ...ELECTRONICS Samsung Electronics Co Ltd May 2000 Printed in Korea DE68 01203A...