KS57C0302
USER'S MANUAL ERRATA
JUNE 1998
5. TIMERS AND TIMER/COUNTERS (Page 11-4)
Table 11-2. Basic Timer Mode Register (BMOD) Organization
BMOD.3
Basic Timer Restart Bit
1
Restart basic timer; clear IRQB, BCNT, and BMOD.3 to "0"
BMOD.2
BMOD.1
BMOD.0
Basic Timer Input Clock
Interrupt Interval Time
(5)
0
0
0
fx/2
12
(1.02 kHz)
2
20
/fx (250 ms)
0
1
1
fx/2
9
(8.18 kHz)
2
17
/fx (31.3 ms)
1
0
1
fx/2
7
(32.7 kHz)
2
15
/fx (7.82 ms)
1
1
1
fx/2
5
(131 kHz)
2
13
/fx (1.95 ms)
NOTES
:
1.
Clock frequencies and stabilization intervals assume a system oscillator clock frequency (fx) of 4.19 MHz.
2.
Oscillation stabilization time is the time required to stabilize clock signal oscillation after stop mode is released.
3.
The standard stabilization time for system clock oscillation following a
RESET
is 31.3 ms at 4.19 MHz.
4.
Interrupt interval time is the wait time when STOP mode is released.