Troubleshooting_37
Check Type
Check Mode
Checking Method
Corrective actions
Power Check
None
1. Check the connections for the power cable.
- Reconnect the power cable.
2. Check the voltage of the power outlet.
● Normal: AC 120V
- Connect to a 120V power source.
3.Check the wires of the Main PBA power part.
- Measure the voltage between the
of CN01.
● Normal: AC 120V
- Faulty: Check and replace the wires of the power part.
- Check voltage
4. Check the DC voltage of the Main PBA.
- See “Main PBA DC voltage Check”.
Main-PBA DC
Voltage Check
None
Check the DC voltage of the Main PBA.
Measure the voltage between pin 1 (PINK) and pin 3 (BLUE)of the
main PBA CN6 connector
Normal (Door Close): 0V
Normal (Door Open): 11.4V to 12.6V
●
●
Check voltage:11.4V to 12.6V
pink wire and blue wire