Installation
Installation
English
30
Check code
Meaning
Solution
0
Vent condition is good.
Clg (Cg)
The vent is clogged.
1.
Clean the lint filter.
2.
Check your vent condition.
* You must take measures (such as
cleaning) through expert personnel.
C80 (C8)
About 80 % of the vent is clogged.
(This may decrease the drying
performance.)
C90 (C9)
Over 90 % of the vent is clogged.
(This may lead to poor drying
performance or cause malfunction)
Ct
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
or too high (over 104 °F (40 °C)) and
therefore vent blockage cannot be
detected.
Leave the dryer at room
temperature (41~95 °F (5~35 °C))
for an hour and check again.
tC
Temperature sensor error
Contact a service center.
C1
Unit is detecting items inside the
drum or there is an error on the dry
sensor.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
dC
Unit is detecting door is open
Close the door properly and check
again.
If the problem continues, contact a
service center.
9C1
Abnormal voltage detected
Check the power connection. (Refer
to the “
section)
If the problem continues, contact a
service center.
DV3200T_DC68-03784N-00_EN.indd 30
2020-05-25 11:10:20
Содержание DVE45T3200 Series
Страница 1: ...Dryer User manual DVE G 45T3200 DV3200T_DC68 03784N 00_EN indd 1 2020 05 25 11 10 17 ...
Страница 57: ...Sèche linge Manuel d utilisation DVE G 45T3200 DV3200T_DC68 03784N 00_CFR indd 1 2020 05 25 11 29 05 ...
Страница 113: ...Secadora Manual del usuario DVE G 45T3200 DV3200T_DC68 03784N 00_MES indd 1 2020 05 25 11 10 48 ...