Installation requirements
English
21
WARNING
Risk of Electric Shock
When local codes allow, you can connect
the dryer’s electrical supply with a new
power supply cord kit, marked for use with
a dryer, that is U.L. listed and rated at a
minimum of 120 / 240 volts, 30-amperes
with three No. 10 copper wire conductors
terminated with closed loop terminals,
open-end spade lugs with turned up ends,
or with tinned leads.
• Do not reuse a power supply cord from
an old dryer. The power cord electric
supply wiring must be supported at the
dryer cabinet by a suitable UL-listed
strain relief.
• Grounding through the neutral
conductor is prohibited for (1) new
branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and
(4) areas where local codes prohibit
grounding through the neutral
conductor. (Use a 4-prong plug for a
4 wire receptacle, NEMA type 14-30R.)
Electric models – Canada Only
A 120 / 240 volt, 60 Hz AC approved
electrical service fused through a
30-ampere fuse or circuit breaker on both
sides of the line is required.
NOTE
All Canadian models are shipped with
the power cord attached. The power cord
should be plugged into a 30-ampere
receptacle. In Canada, you may convert a
dryer to 120 / 208 volts.
DV3200T_DC68-03784N-00_EN.indd 21
2020-05-25 11:10:19
Содержание DVE45T3200 Series
Страница 1: ...Dryer User manual DVE G 45T3200 DV3200T_DC68 03784N 00_EN indd 1 2020 05 25 11 10 17 ...
Страница 57: ...Sèche linge Manuel d utilisation DVE G 45T3200 DV3200T_DC68 03784N 00_CFR indd 1 2020 05 25 11 29 05 ...
Страница 113: ...Secadora Manual del usuario DVE G 45T3200 DV3200T_DC68 03784N 00_MES indd 1 2020 05 25 11 10 48 ...