Disassembly and Reassembly _ 21
3-3. HOW TO REPLACE NATURAL GAS TO LP
Figure
Description
•
ITEM CODE : LPKIT-3/XAA(DC99-00792A)
•
ORIFICE SPUD NO. 54
•
For 22,000 BTU Gas Valve
•
ITEM CODE : LPKIT-4/XAA(DC98-04114A)
•
ORIFICE SPUD NO. 55
•
For 20,000BTU Gas Valve
※
Fragile. Handle with care
1. Shut off gas supply to dryer if connected and
disconnect power supply cord.
2. Take the BURNER apart from the dryer.
Use care in removal to avoid damage to
the igniter.
3. Remove the screw in red circle and take the
TUBE BURNER apart from the BURNER.