3-WIRE system connections

A. 

External ground connector

B. 

Neutral grounding wire (green/yellow)

C. 

Center silver-colored terminal block screw

D. 

Neutral wire (white or center wire)

E. 

¾” (1.9 cm) UL-listed strain relief
1.  Loosen or remove the center terminal block screw.
2.  Connect the neutral wire (white or center wire) of the power cord to the center, silver-

colored terminal screw of the terminal block. Tighten screw.

3.  Connect the other wires to outer terminal block screws. Tighten screws.
4.  Tighten the strain relief screws.
5.  Insert the tab of the terminal block cover into your Dryer’s rear panel slot.  

Secure the cover with a hold-down screw.
If converting from a 4-wire electrical system to a 3-wire, the ground strap must be 
reconnected to the terminal block support to ground the Dryer frame to the neutral 
conductor.

4-WIRE system connections

A. 

External ground connector

B. 

Green or bare copper wire of power cord

C. 

¾” (1.9 cm) UL-listed strain relief

D. 

Center silver-colored terminal block screw

E. 

Neutral Grounding wire (green/yellow)

F. 

Neutral wire (white or center wire)
1.  Remove the External ground connector screw.
2.  Connect the ground wire (green or unwrapped) of the power cord to the external 

ground connector screw. If you want to connect B(Green or bare copper wire of power 
cord) to the Neutral Post without assembling with A(cabinet ground), call the service 
technician.

3.  Loosen or remove the center terminal block screw.
4.  Connect the neutral wire (white or center wire) of the power cord and the appliance 

ground wire (green with yellow stripes) under the central screw of the terminal block.

5.  Connect the other wires to the outer terminal block screws. Tighten screws.
6.  Tighten the strain relief screws.
7.  Insert the tab of the terminal block cover into your Dryer’s rear panel slot. 

Secure the cover with a hold-down screw.

TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before 
servicing, unless testing requires power.

[HUDSON]_Technical_information-03171A_EN.indd   11

2012-02-03   �� 5:01:24

Содержание DV400EWHDWR/AA

Страница 1: ...power to dryer before servicing unless testing requires power Code No DC68 03171A_EN Due to possibility of personal injury or property damage always contact an authorized technician for servicing or repair of this unit Refer to Service Manual DV456 DV422 DV400 for detailed installation operating testing troubleshooting and disassembly instructions HUDSON _Technical_information 03171A_EN indd 1 201...

Страница 2: ...n wire terminals in Door Sense circuit bE DV422 DV400 bE2 Invalid state of key circuit short for 30 secs Check for Display PCB key circuit short or not FE Invalid power source Frequency Check for Not using regular power source frequency Invalid power frequency sense circuit AE Electronic Control Problem Communication Error Check for Check PCB and Wire harness Replace PCB Et Invalid state of EEPROM...

Страница 3: ...g cycle will not be influenced Sensor Bar Touch Data Mode Definition of Sensor Bar Touch Data Mode This action will put the dryer into sensor bar touch data mode Dryer will display Sensor Bar data This mode is default mode of entering service mode How to Enter With Power On pressing Wrinkle Prevent and Temp Keys for 3 seconds Cycle Count Mode Definition of Cycle Count Mode This mode is to bring up...

Страница 4: ...n Key in this mode Display Mode ID will be decreased Converting C F Celsius C 30 10 10 30 50 70 F 9 5C 32 Fahrenheit F 22 14 50 86 122 158 System Check Mode Definition of System Check Mode t2 will display System Check Mode t2 mode Progress Function Performed Start Pause Motor CW Relay On Heater Relay On Heater Relay Off Motor CW Relay Off How to Enter While in Power Off pressing the Dry Level Powe...

Страница 5: ...er ence of the human body and dryer by contacting the power supply plug when the work contacting to PCB is executed 2 As the P C B assembly is designed for no trouble do not replace the P C B assembly by the wrong diagnosis and follow the procedure of the trouble diagnosis when the micom is not operated normally ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock personal injury or...

Страница 6: ...he motor protector normal If above points are not found the PCB assembly is out of order Replace it 5 Blows fuses or trips circuit breaker Gas Model During ignition the dryer will draw X amps With the burner ON the dryer will draw X amps If the dryer is drawing amperages above this then the house wiring fuse box or circuit breaker is suspected to be at fault Igniter harness loose and shorted to ba...

Страница 7: ...in exhaust Outside exhaust hood damper door stuck closed Exhaust too long too many elbows flex ductwork installed Poor intake air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower impeller bound check for foreign material in blower area Customer overloading dryer Check clothing labels for fabric content and cycle selected Clothes too wet due to insufficient spin out by w...

Страница 8: ...ce is infinity replace thermostat 2 Heater resistance 10 Ω If resistance is infinity replace Heater Measure resistance of the following terminal 1 Door switch open Terminal COM NC 1 3 1Ω Terminal COM NO 1 2 Ω 2 Door switch push On Terminal COM NC 1 3 Ω Terminal COM NO 1 2 1Ω Belt Cut off S W Lever open Resistance value 1Ω Lever push Resistance value Ω Lamp resistance 80 100 Ω Blue White Motor Elec...

Страница 9: ...ite replace Radiant sensor Igniter 101D Resistance value 40 400 Ω If resistance is infinite replace Igniter Gas Valve 25M01A Valve 1 2 Resistance value 1 2K Ω Valve 1 3 Resistance value 0 5K Ω Valve 4 5 Resistance value 1 2K Ω If resistance is infinity replace Valve Thermostat 60T21 Hi Limit 230F 50F Resistance value 1 Ω If resistance is infinity replace Thermostat HUDSON _Technical_information 03...

Страница 10: ... Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5 Approx Ω without laundry Approx 190Ω 10 with wet clothes Cycling Thermostat Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6 Approx 10 KΩ at 25 C 77 F CN1 1 AC Power Port 2 Door Detection Sensor 3 Motor Switch Sensor RY7 Heater Relay Switch RY5 Motor Relay Switch HUDSON _Technical_information 03171A_EN indd 10 2012 02 0...

Страница 11: ...L listed strain relief D Center silver colored terminal block screw E Neutral Grounding wire green yellow F Neutral wire white or center wire 1 Remove the External ground connector screw 2 Connect the ground wire green or unwrapped of the power cord to the external ground connector screw If you want to connect B Green or bare copper wire of power cord to the Neutral Post without assembling with A ...