4. Alignment and Troubleshooting
Depth1
Depth2
Meaning
0000-LSU Motor 1
Rdy
Detects if LSU motor1 runs at normal speed.
0010-LSU Motor 2
Rdy
Detects if LSU motor2 runs at normal speed.
0060-LSU Motor 1
Run
LSU Motor1 On/Off
0070-LSU Motor 2
Run
LSU Motor2 On/Off
0080-LD Power 1
LSU LD1 enable On/Off (yellow)
0090-LD Power 2
LSU LD2 enable On/Off (magenta)
0100-LD Power 3
LSU LD3 enable On/Off (cyan)
110-LSU
0110-LD Power 4
LSU LD4 enable On/Off (black)
112-ACR
0010-Manu Regi Clear
Clear Manual Offset Value of Color Regi.
•
Manual Settings
This menu can set up the offset manually.
•
Regi Pattern
This menu can print the regi pattern.
4-23
Copyright© 1995-2016 SAMSUNG. All rights reserved.