4. Alignment and Troubleshooting
► Error Code
U2–6142
U2–6143
► Error message
Error: #U2-6142 / LSU Unit Failure: #U2-6142. Turn off then on.
Error: #U2-6143 / LSU Unit Failure: #U2-6143. Turn off then on.
► Symptom
LSU H sync signal is abnormal.
► Troubleshooting method
※
First, turn the machine off then on. If the error persists, refer to the following.
1) Check if the LSU connector on the main board is connected correctly.
2) If the connection is OK, replace the LSU.
3) If the problem persists, replace the main board.
4-59
Copyright© 1995-2016 SAMSUNG. All rights reserved.