24
10. DESIGNATION OF MAIN COMPONENTS
10-1 Normal / Reverse Revolution of Motor and R. P. M. Control
10-2 Door safety Device
When Door is closed, door stay closed. if "set" is operated, power supplied to
,
wires have bymetal keep
the door closed, and electronical power flows between
and
make it operate.
+
-
8
9
5
10
Rotor
Stator coil
CW
+
-
8
9
5
5
10
Rotor
Stator coil
CCW
<Figure1>
<Figure2>
1 2 3 4 5 6 7 8 9 10
STATOR
WASHING MOTOR
T
A
C
H
O
H
IG
H
-S
P
E
E
D
S
T
A
T
O
R
P
R
O
T
E
C
T
O
R
M
ID
D
L
E
-S
P
E
E
D
R
O
T
O
R
(1
50
C
)
H
(
± 7%)
STATOR(5.1) STATOR(5.1) ROTOR(8.9) TACHO(3.4) PROTECTOR(6.7) "H"(mm)
Code-No.
Remark
Resistance
value
2.07
Ω
0.90
Ω
2.35
Ω
34.3
Ω
0
45
DC31-00002F
B1445AV,B1245AV,
B1045A
Rated
value
220~240V/50Hz
Содержание B1045AGW/YLW