12
6. TECHNICAL POINT
5) The other water level data
※
If water level is 15KHZ below or 30 KHZ above , Sensor-pressur is out of order so needs changing.
The water data unter each conditon
B1445AV , B1245AV, B1045A
1st water supply (only preparation)
25.50
1st water supply level to washing tub
Overflow error
21.50
The water supplied reach 2/3 of door
Bubble
detectingatwashing/rinse/dehydrating
24.50
Bubble -detecting water level
Bubble detecting rinse water level
23.00
The water level which can detect bubbles
Water level which can open door
24.80 over
It is possible to open the door
Water level which can drive heater
25.50
Safety water level of wash heater
Water level which can reset the drain
25.50
The water level can be detected after 1st draining
unit:Khz