15
English
Installation
CAUTION
•
Make sure that the connection parts are not exposed
to outside.
•
Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials
that have the same level of withstand voltage with
the power cable. (Comply with the local regulations
on extensions.)
WARNING
•
In case of extending the electric wire, please DO
NOT use a round-shaped pressing socket.
–
Incomplete wire connections
can cause electric shock or
a fire.
Step 2.5 Installing and connecting
the drain hose
1
Install the drain hose.
Drain hose
Assembly pipe
Connection hose
Wall
5 cm
less
Ditch
Water
Slant downwards
Slant upwards
Dipped in water
Bent
Too small
clearance
Too small
clearance
Indoor unit
Drain hose
2
Pour water into the drain pan. Check whether the
hose is well drained.
CAUTION
•
Make sure that the indoor unit is in upright
position when you pour water to check for leakage.
Make sure that the water does not overflow onto
the electrical part.
•
If the diameter of the connection hose is smaller
than the product's drain hose, water leakage may
occur.
•
Inadequate installation may cause water leakage.
•
If the drain hose is routed inside the room,
insulate the hose so that dripping condensation
does not damage the furniture or floors.
•
Do not box in or cover the drain hose connection.
Drain hose connection must be easily accessible
and serviceable.