Checking auxiliary power switch
Turn on the auxiliary power switch which is installed separately.
ON
1 phase circuit breaker
3 phase 4 wire circuit breaker
Auxiliary power switch(ELCB, ELB)
• Auxiliary power switch is not included in the package. Purchase and install it separately.
• Auxiliary power switch is a device for preventing over-current or short circuit. Turn off the auxiliary power switch
when you are cleaning the product or not going to use the product for long period of time.
• If ELB has already been installed in the switch box of the building, it is not mandatory for you to install the
auxiliary power switch.
NOTE
Operational temperature and humidity range
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table
for efficient use.
Mode
Indoor temperature
Outdoor temperature
Indoor humidity
Cool
18 °C ~ 32 °C
-10 °C ~ 43 °C
Relative humidity 80% or less
Dry
18 °C ~ 32 °C
-10 °C ~ 43°C
-
f
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
ENGLISH-11