background image

ENGLISH-7

01

 

Pr

EP

ar

at

ION

Choosing the installation location

Indoor unit

 

Install the unit at a place close to the wall facing the outside as it is necessary to perform piing connection with the 
outdoor unit .

 - It is effective to install the unit at the place where air flow is not blocked and the cool air can be distributed throughout 

the room . 

 

Install the unit at a place where there is no obstacle against the wind around the air intake and air outlet .

 

Avoid a place near the door which is frequently used by people .

 

Avoid a place exposed to direct sunlight . (If it is unavoidable, install a sunshade) .

 - Surface of the product may get discolored .

Install it on even ground .
•  Make sure there is no abnormal operation or noise generation .
•  If installed on uneven ground, water may overflow .

Outdoor unit

 

Avoid a place exposed to direct sunlight . (If it is unavoidable, install a sunshade) .

 

A place free from the risk of combustible gas leakage .

 

A place which can bear the weight of the unit .

 

A place which can bear the fixing strength of the outdoor unit .

 

Avoid a place exposed to oil (including machine oil)

 

Avoid a saline place .

 

Avoid a place exposed to sulfide gas (hot spring zone) . 

 - When installing the unit at such special environmental conditions, it may cause trouble to the product . When it is 

unavoidable, special maintenance is required .

 

A place where discharged air and noise of the outdoor unit does not disturb the neighborhood .

 - Take extra care not to cause any inconvenience to your neighbors when installing the unit on the borderline with your 

neighborhood .

 

A place where strong wind does not head against the air outlet of the outdoor unit .

 - If a strong wind heads directly against the air outlet at the time of cool operation, a safety device can be operated .

Do not install the outdoor unit on a unstable places (such as rooftop) . If installation is unavoidable, make sure that you 
fixed the unit firmly . Avoid places where strong wind or storm can possibly knock down the product (such as seashore or 
place with frequent storm)

FAC MEMORY-EU_IM_04036A-03_EN.indd   7

2016-03-30   오전 10:58:21

Содержание AF**FSSDA Series

Страница 1: ...s AF FSZDA Series Air Conditioner installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct DB68 04036A 04 EN EL ES FR IT PT DE FAC MEMORY EU_IM_04036A 03_EN indd 25 2016 0...

Страница 2: ...11 Installation Drilling a hole and fixing the indoor unit 12 Connecting pipes 12 Connecting drain hose 15 Electrical work 16 Vacuum pump 20 Performing leak test 21 Installing the earth wire 21 Charg...

Страница 3: ...outdoor units securely and attach the wires firmly to the terminal block connecting sections so that the pressure is not applied to the sections Inappropriate connection and fixing could cause fire A...

Страница 4: ...eck if the product is in good shape before the installation Do not install the product with the damage which occurred during shipment Read the installation manual thoroughly before installing the air...

Страница 5: ...when provisions of the installation manual are not complied with the cost required to access and repair the units in SAFETY CONDITIONS as set out in prevailing regulations with harnesses ladders scaff...

Страница 6: ...rque wrench 3 Pipe cutter 4 Reamer 5 Pipe bender 6 Spirit level 7 Screw driver 8 Spanner 9 Drill 10 L wrench 11 Measuring tape Tools for test operations 1 Thermometer 2 Resistance meter 3 Electroscope...

Страница 7: ...which can bear the weight of the unit A place which can bear the fixing strength of the outdoor unit Avoid a place exposed to oil including machine oil Avoid a saline place Avoid a place exposed to s...

Страница 8: ...longer try to minimize the piping length but make sure it is over 5 m Select the installation location where you can keep the piping bending to maximum 10 spots Stated cooling performance is based on...

Страница 9: ...r piping 60 cm or more Fixing outdoor unit Follow below method to firmly fix the outdoor unit Using rubber leg Put the rubber leg to the outdoor unit leg Refer to illustration on the right Using ancho...

Страница 10: ...n Make sure to check for proper drainage in defrost operation Do not install on the place where bottom part of the outdoor unit is at lower level than the drain hose When installing the drain hose for...

Страница 11: ...ries Rubber leg Main power cable Indoor outdoor unit communication cable Indoor Outdoor unit power cable Drain plug Installation accessories Drain connection hose Connection pipe Insulation 6 35 mm Co...

Страница 12: ...ing make sure there is no leakage When recovering the refrigerant stop the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor wor...

Страница 13: ...e of the outdoor unit and tightening by applying appropriate torque Flare process 1 Cut the pipe using the pipe cutter Oblique Rough Burr 90 2 Remove burr on the edge of the pipe If burr is not remove...

Страница 14: ...to perform leak test Refer to Performing leak test on pagSe 21 6 Insulate the drain hose after connecting it Insulate it correctly to avoid dew formation Pipe insulation 1 Insulate the refrigerant pi...

Страница 15: ...owever if extension is unavoidable due to its short length use silicone sealant to securely seal the connection to prevent leakage Do not use the insulation tape CAUTION Duct drainage Polypropylene PP...

Страница 16: ...ure to connect earth wire type Indoor unit Indoor power Indoor outdoor unit power cable Outdoor unit Outdoor power Earth leakage circuit breaker Power 1Ph 220 240V 50 60 Hz Circuit breaker 20 A Indoor...

Страница 17: ...d part of the terminal should face upward Installed back to front Compressed part is cut Ring terminal is detached After tightening there should be no gap between a terminal and a screw If there is a...

Страница 18: ...s refer to the installation manual CAUTION Unit mm 120 60 20 20 20 180 Power cable provided by us 20 Wire tube power cable 3 Insert both sides of core wire of the power cable into the connection sleev...

Страница 19: ...mpleted wrap it with the insulation tape to finish Make sure that the connection parts are not exposed to outside Be sure to use insulation tape and a contraction tube made of approved reinforced insu...

Страница 20: ...r 4 After degree of vacuum has been established open the service valve 1 2 as shown in the illustration Use soapsuds to check for refrigerant leakage on the connection part of the pipes 2 1 F T Conden...

Страница 21: ...cted to indoor outdoor units and check the connection part of the indoor outdoor units with soap lather or liquid for leakage test Tightening torque for charging port cap Refer to the table Tightening...

Страница 22: ...mation regulation regarding the refrigerant used This product contains fluorinated greenhouse gases Do not vent gases into the atmosphere Inform users if system contains 5 tCO2e or more of fluorinated...

Страница 23: ...outdoor unit over 21 C operate in Cool mode for over 10 minute 6 While pressing and holding the Set Cancel button on the remote controller press the Power button for 3 seconds to display the temperatu...

Страница 24: ...FAC MEMORY EU_IM_04036A 03_EN indd 24 2016 03 30 10 58 30...

Отзывы: