ENGLISH-16
Electrical work
• The electrical work should be performed by a specialist qualifi ed for the work .
• Avoid using multi-concent but use rate power supply for air conditioner . (Use separate power cable for outdoor
unit .)
CaUtION
Wiring standard
▶
Always make sure that the power supply is compliant with current safety standards . Always install the air conditioner
incompliance with current local safety standards .
▶
Make sure to install exclusive power supply(purchase separately) .
- If you use multiple connecting, there is a risk of electric shock or fi re .
▶
If the outdoor power supply has been selected, install circuit breaker (ELCB) . (Purchased separately)
▶
Make sure to connect earth wire .
type
Indoor unit
Indoor power (Indoor/outdoor unit power cable)
Outdoor unit
Outdoor power (Earth leakage circuit breaker)
Power
1Ph, 220~240 V, 50/60 Hz
Circuit breaker
20 A
Indoor/outdoor unit power cable
1 .0 mm
2
or more
Outdoor unit power cable
2 .5 mm
2
or more
Indoor/outdoor unit communication cable
0 .75 mm
2
or more
Connecting procedure
1 . After loosening the 4 screws(
1
) of support-inlet, disassemble the support-inlet .
2 . Connect the housings of communication cable(
2
) for an indoor unit and outdoor unit .
3 . Fix the power connection cable and communication cable with a cable clamp .
4 . After assembling the SUPPORT-INRET and fi x it with the screws(
1
) .
COVER-PCB
Screw
1
SUPPORT- INLET
Power connection cable
Communication
cable
Earth plate
Power terminal
Cable clamp
Housing
2
FAC MEMORY-EU_IM_04036A-03_EN.indd 16