Troubleshooting
DISPLAY
EXPLANATION
Outdoor sensor error (Short/Open)
Outdoor A cond pipe sensor er ror (Short/Open)
Outdoor B cond pipe sensor er ror (Short/Open)
Outdoor C cond pipe sensor er ror (Short/Open)
A unit test operation error
B unit test operation error
C unit test operation error
A unit test communication error
B unit test communication error
C unit test communication error
A,B,C unit all communication er ror
A room test operation OK
B room test operation OK
C room test operation OK
Communication unit number display : A unit
Communication unit number display : B unit
Communication unit number display : C unit
(In case of triple split multi air conditioner)
REMARK
Be sure to check after applying the power
to the outdoor unit.
Be sure to check during the test operation.
Display of power application.
Display 4 minutes after the COMP is on.
•Normal operation
Unit A,B and C are changed every one second.
The communication lamp is flickering after
display of each unit.
(possibility to check the communication status)
•During the test operation the unit under test
is on and off every 0.25s.
Display when the test operation finishes.
• When the pipe temperature difference of
indoor unit (pipe temperature 4 minutes before
- Actual pipe temperature) is less than 5˚C.
Содержание AD18A1(B1)E09
Страница 2: ... Samsung Electronics Co Ltd NOV 1998 Printed in Korea Code No DB81 10179A 1 ...
Страница 4: ...1 2 Samsung Electronics MEMO ...
Страница 26: ...3 18 Samsung Electronics MEMO ...
Страница 42: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit ...
Страница 50: ...Samsung Electronics 7 1 7 PCB Diagrams 7 1 Main PCB ...
Страница 54: ...Samsung Electronics 8 2 8 2 Outdoor Unit UD24A1 B1 E2 UD18A1 B1 E2 UD19A1 B1 E2 ...
Страница 56: ...Samsung Electronics 9 1 9 Schematic Diagrams 9 1 Indoor Unit ...
Страница 57: ...9 2 Remote Control Samsung Electronics 9 2 ...