27
English
Installation Pr
oc
edur
e
Option
SEG19
Ɗkߤߢࠍࣕ
Ɗkߤߣࠎࣕ
SEG22
Ɗkߤߥࠏࣕ
SEG24
Function
Page
Individual control with remote
control
Heating setting
compensation
Reserved
Setting the MDS Kit installation option
Reserved
Indication
and
details
Indication Details Indication
Details
Indication Details
Indication
Details
3
0 or 1
Indoor 1
0
Default
0
Disuse (Soft Off+Hard off)
Standard
1
Off after 20 min. (Soft Off+Hard off)
2
Off after 40 min. (Soft Off+Hard off)
2
Indoor 2
1
2°C
3
Off after 80 min. (Soft Off+Hard off)
Premium
4
Off after 20 min. (Soft Off+Hard off)
5
Off after 40 min. (Soft Off+Hard off)
6
Off after 80 min. (Soft Off+Hard off)
3
Indoor 3
2
5°C
Standard
7
Off after 20 min. (Soft Off only)
8
Off after 40 min. (Soft Off only)
9
Off after 80 min. (Soft Off only)
4
Indoor 4
Premium
A
Off after 20 min. (Soft Off only)
B
Off after 40 min. (Soft Off only)
C
Off after 80 min. (Soft Off only)
•
1) SEG8
Even if you set the Use of drain pump option to 0, it is automatically set to 2 (the drain pump is used with 3 minute
delay).
•
2) SEG18
If you set the Maximum filter usage time option to a value other than 2 and 6, it is automatically set to 2 (1000 hours).
•
3) SEG20
If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0
(Indoor 1).
•
4) SEG21
Default value of Heating setting compensation is 5 °C.
•
5) SEG23
Soft Off
: The indoor unit turns off its operation at the indicated time in the table for Installation Option after its final
motion detection. But, it turns on again if the MDS detects motion.
Hard Off
: Designated time after SOFT OFF, it cannot turn on automatically when it detects motion. Users should
control to turn on the indoor unit with remote control, etc.