www.samsungehs.co.uk
©G Hendra April 2015
12
Setting the Clock
Press the grey set button for 5 seconds.
The day will flash, adjust this with the silver up and down
buttons, press grey set.
The hours will flash adjust this with the silver up and down
buttons, press grey set.
The minutes will flash, adjust this with the silver up and
down buttons, press grey set you are back to the normal
screen.
Field Settings
Field settings are what define how the unit is configured and how it will work, each system
can have very different field settings.
Many field settings will need to be made: NOTE the set button is the grey one not the
blue
Field settings are in groups the 20s are for weather compensation and temperature control in
heating, the 30s are for the cylinder and the 40s are for backup boilers and hybrid systems.
Below are the field setting specific to your system as described in this book.
Enter field settings by pressing
test
for 6 seconds, 10 will show
on the screen
Scroll up to 20 using the silver up button, press
set
, 2011 will
show.
To adjust this setting press
set
again the setting will appear at
the top of the screen, adjust it with the silver up down buttons
and press
set
again, scroll up to the next field setting using the
up and down buttons and repeat.
When you have finished all your 20 settings press
cancel delete
once, 20 will show on the screen, press the silver up button to
move to the 30s and repeat the procedure above.
When finished or if you get lost press cancel delete 2 x to return
to the normal screen
Note: if you set a field setting and go back to check it, it will not
have changed, the field setting do not get written to the PCB until you finish setting and exit.