Design and principle of operation
Type 3730-3 Positioner
The technical data for the explosion-protected devices may be restricted by the
limits specified in the test certificates.
Influences
Temperature
≤0.15 %/10 K
Supply air
None
Effect of vibration
≤ 0.25 % up to 2000 Hz and 4 g according to IEC 770
Electromagnetic compatibility
Complying with EN 61000-6-2, EN 61000-6-3, EN 61326-1 and NAMUR
Recommendation NE 21
Electrical connections
One M20x1.5 cable gland for 6 to 12 mm clamping range
Second M20x1.5 threaded connection additionally available
Screw terminals for 0.2 to 2.5 mm² wire cross-section
Degree of protection
IP 66/NEMA 4X
Use in safety-instrumented
systems (SIL)
Emergency venting at 0 mA set
point and using optional
solenoid valve
Observing the requirements of IEC 61508, the systematic capability of the pilot
valve for emergency venting as a component in safety-instrumented systems is
given.
Use is possible on observing the requirements of IEC 61511 and the required
hardware fault tolerance in safety-instrumented systems up to SIL 2 (single device/
HFT = 0) and SIL 3 (redundant configuration/HFT = 1).
Explosion protection
Refer to Table 14
Communication (local)
SAMSON SSP interface and serial interface adapter
Software requirements (SSP)
TROVIS-VIEW with database module 3730-3
Communication (HART
®
)
HART
®
field communication protocol
Impedance in HART
®
frequency range: Receiving 350 to 450 Ω · Sending approx.
115 Ω
Software
require-
ments
For handheld
communicator
Device description for Type 3730-3
For computer
DTM file according to specification 1.2, suitable for integrating the device into
frame applications that support the use of FDT/DTM (e.g. PACTware); other
integrations (e.g. AMS, PDM) available
Binary contacts
For connection to
For connection to the binary input of the PLC acc.
to IEC 61131-2, P
max
= 400 mW or for connection
to NAMUR switching amplifier acc. to EN 60947-
5-6
NAMUR switching amplifier
acc. to EN 60947-5-6
Two software limit switches, reverse polarity protection, floating, configurable switching characteristics (default set
-
tings in table)
Signal
state
Version
No explosion protection
Ex
No response
Non-conductive
≤1.0 mA
Response
Conductive (R = 348 Ω)
≥2.2 mA
Содержание TROVIS 3730-3
Страница 38: ...38 EB 8384 3 EN...
Страница 40: ...40 EB 8384 3 EN...
Страница 80: ...80 EB 8384 3 EN...
Страница 94: ...94 EB 8384 3 EN...
Страница 118: ...118 EB 8384 3 EN...
Страница 124: ...124 EB 8384 3 EN Decommissioning and removal...
Страница 146: ...146 EB 8384 3 EN...
Страница 150: ...150 EB 8384 3 EN...
Страница 151: ...EB 8384 3 EN 151...
Страница 152: ...152 EB 8384 3 EN...
Страница 153: ...EB 8384 3 EN 153...
Страница 154: ...154 EB 8384 3 EN...
Страница 155: ...EB 8384 3 EN 155...
Страница 156: ...156 EB 8384 3 EN...
Страница 157: ...EB 8384 3 EN 157...
Страница 158: ...158 EB 8384 3 EN...
Страница 159: ...EB 8384 3 EN 159...
Страница 160: ...160 EB 8384 3 EN...
Страница 161: ...EB 8384 3 EN 161...
Страница 162: ...162 EB 8384 3 EN...
Страница 163: ...EB 8384 3 EN 163...
Страница 164: ...164 EB 8384 3 EN...
Страница 165: ...EB 8384 3 EN 165...
Страница 166: ...166 EB 8384 3 EN...
Страница 167: ...EB 8384 3 EN 167...
Страница 168: ...168 EB 8384 3 EN...
Страница 169: ...EB 8384 3 EN 169...
Страница 170: ...170 EB 8384 3 EN...
Страница 171: ...EB 8384 3 EN 171...
Страница 177: ...EB 8384 3 EN 177...
Страница 178: ...178 EB 8384 3 EN...
Страница 179: ...EB 8384 3 EN 179...