20
EB 9527-3 EN
Operation
Further details on the display and operating controls can be found at the back of these in-
structions.
6.1.1
Switching over to display mode
Depending on the operating mode, each pressing of the
key allows you to switch between
the default display and up to eight other display readings.
After eight seconds or after the text has finished running across the display, the display auto-
matically returns to the default display.
GKZ
Default mode (e.g. gas code (O
2
) and actual content)
∆p
Current differential pressure
MCN
Max. capacity nominal
MCN/R
100 % tank volume or max. possible flow rate at 20 mA signal
SCN
Save capacity nominal. Geometric tank volume up to overflow/gauge pipe.
SCN/R
100 % tank volume at 20 mA signal
UCW
Useable capacity work
Δp100
Maximum differential pressure
Δp0
Minimum differential pressure
PTANK
Nominal tank pressure. Value corresponds to the pressure assigned to the density (liquid)
according to the steam pressure graph. If
MCN
and
SCN
are calculated on the basis of
1 bar, '1 bar' is displayed for
PTANK
.
TKZ
Tank/plant identifier
FLOW
Flow rate
ERROR
Error code automatically displayed in the event of an error (see section 10).
OFF
Special signal on opening the equalizing valve, I = 3.6 mA
LOW BAT
Special signals in battery operation
BAT MODE
Battery mode
EMS
Power-saving mode (ESM). 4 to 20 mA signal deactivated.