background image

 

 

 

8 of 9 

Specifications subject without notice 

Edition: August 2017

 

Operating instructions  BA 14b-02_EN 

 

 

5.  Pressure check in pipeline section 

The pressure check of valves has already been carried out by the manufacturer. To check the pressure of a section of pipeline 
with installed valves, the following points must be observed: 

 

Carefully flush newly installed pipes to remove any foreign material before operating the valve. 

 

Valve OPEN:

 The test pressure should not exceed the value 

1.5 x PN

 (see nameplate).  

 

Valve CLOSED:

 The test pressure should not exceed the value 

1.1 x PN

 (see nameplate). 

If a valve leaks, see section 7 <Troubleshooting>. 

 
 

6.  Standard operation and maintenance 

 

Depending on the design and construction in use, the operating shaft sealings are maintenance free 

The operating shaft with a PTFE-V-ring pack sealing, is pre-loaded with a spring washer set, and therefore  

 

maintenance free 

The operating shaft with PTFE-meshwork pack sealing is pre-loaded with a compression spacer and must only be 

 

adjusted when required 

 

Normal manual force is sufficient to operate the manual operation. Turn the handwheel clockwise to close the valve. It is 
not permissible to use extensions to increase the operation torque. 

 

Note 

Butterfly valves with lever: 

The position of the lever indicates the valve’s position:  
Lever at a 90° angle to the pipeline: 

Valve CLOSED, 

Lever parallel to the pipeline: 

Valve OPEN.

 

 

Danger 

Butterfly valves with lever: 

Do not open and close the valve with sudden movements, but quick enough to prevent pressure surges and/or 
temperature shocks occurring in the pipeline. 

Failure to follow these safety precautions may result in personal 

injury and can damage equipment installed in the pipeline. 

 

 

Regular maintenance work on the butterfly valves is not necessary. When checking the pipeline section, make sure that no 
medium leaks out at the flanged and threaded ends of the body and at the shaft packing. 

 

If a valve leaks, proceed as described in section 7 <Troubleshooting>. 

 
 

7.  Troubleshooting 

Observe the safety instructions listed in section 2 on troubleshooting. 

 

Warning

 

To remove a valve from a pipeline containing dangerous media and to take it out of the plant:  
Decontaminate the valves properly first. 

 

Содержание BR14a

Страница 1: ...ion 2 3 Applied standards EN 593 AD 2000 Regulations Product standard for butterfly valves Regulations for pressurized valve body parts Type designation and technical features Pfeiffer data sheets TB1...

Страница 2: ...e 3 2 Safety instructions 3 2 1 General safety instructions 3 2 2 Safety instructions for the operator 3 2 3 Particular hazards 4 2 4 Designation of the butterfly valve 5 3 Transport and storage 5 4 I...

Страница 3: ...s have no own potential ignition source after testing the hazardous ignition in accordance to DIN EN 13463 1 Therefore Pfeiffer valves do not come under the directive 2014 34 EU Relating to this direc...

Страница 4: ...butterfly valve over 0 leads to irreparable damage to the sealing ring e g sealing strip this must therefore be avoided Butterfly valves that are operated at temperatures greater than 50 C or lower th...

Страница 5: ...T V Anlagentechnik GmbH Direction of flow Note see note in section 4 2 Installation instructions Table 1 Designation of the butterfly valve Keep the labeling on the valve body and on the nameplate to...

Страница 6: ...ard and abrasive foreign material prior to installation of the butterfly valve 4 2 Installation instructions Store and transport the valve with its protective packing right up to the point of installa...

Страница 7: ...Di1 87 135 183 233 Di2 58 118 166 217 BR14t Di1 53 77 127 172 223 256 Di2 44 59 119 170 221 267 DN 50 80 100 150 200 250 300 600 BR14e Di 26 66 86 140 191 241 290 580 Table 2 Minimum required inside d...

Страница 8: ...sted when required Normal manual force is sufficient to operate the manual operation Turn the handwheel clockwise to close the valve It is not permissible to use extensions to increase the operation t...

Страница 9: ...alve still leaks The valve must be repaired Contact Pfeiffer for spare parts and necessary instructions On loosening or unscrewing the nuts at the stuffing box gland counterclockwise Danger To protect...

Отзывы: