70
EB 8387-5 EN
Operating the positioner
7.7
Reset to default settings
This function resets all start-up parameters to the factory default settings (see code list in sec-
tion 12.3).
Enable configuration:
1.
Turn until Code
3
appears (reading:
OFF
).
2. Press
, the code number
3
blinks.
3.
Turn until
ON
appears.
4. Press
to confirm (reading: ).
Reset start-up parameters:
1.
Turn until Code
36
appears (reading:
OFF).
2. Press
, the code number
36
blinks.
3.
Turn until
RUN
appears.
4. Press
to confirm.
All start-up parameters as well as the
diagnosis are reset to their default values.
Reset
Default: No