10 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 11
MISE EN GARDE!
LA SORTIE DE COURANT SUR LES BORNES DE CHARGE EST LIMITÉE À UN
MAXIMUM DE 20A. SI DES CHARGES PLUS LOURDES TIRENT PLUS DE 20A
COMME UN ONDULEUR, ETC. DOIVENT ÊTRE ALIMENTÉS, CONNECTEZ-LES
DIRECTEMENT À LA BATTERIE VIA LE FUSIBLE APPROPRIÉ «F2» QUI DOIT
CORRESPONDRE AU COURANT D'ENTRÉE CC DE L'ONDULEUR. CE FUSIBLE DOIT
ÉGALEMENT ÊTRE INSTALLÉ À MOINS DE 7 "DE LA BORNE (+) DE LA BATTERIE.
-
Battery Over Voltage (≥16V/32V)
:
• Battery Status LED (
2, Fig 2.1
) will be fast blinking GREEN (
4 Hz
)
• Load will be disconnected. This condition will be automatically reset at 15.0 / 30.0V.
-
Low Voltage - Load Disconnect (≤11.1V/22.2V)
: Battery Status LED (
2, Fig 2.1
) will be steady
RED. Output to Load Terminals will be disconnected. This condition will be auto reset at 12.6/ 25.2V
Protect the load as follows:
-
Overload or short circuit in the load connected to the Load Terminals
: Output
to Load Terminals will be disconnected (
Refer to Sections 5.1.4 & 5.1.5 for details
)
Connect the Positive (+) and Negative (-) of load(s) to controller Load Terminals as shown in Fig 3.2.
3.4.3 Step 3: Solar Panel / Array Connection
WARNING!
RISK OF ELECTRIC SHOCK! EXERCISE CAUTION WHEN HANDLING SOLAR
CONNECTIONS. HIGH VOLTAGE OUTPUT FROM THE SOLAR PANEL(S)/ARRAY
MAY CAUSE SHOCK OR INJURY. COVER THE SOLAR PANEL(S)/ARRAY FROM THE
SUN BEFORE INSTALLING SOLAR WIRING.
MISE EN GARDE!
RISQUE DE CHOC ELECTRIQUE! FAITES PREUVE DE PRUDENCE LORS DE LA
MANIPULATION DE L'ÉNERGIE SOLAIRE CONNEXIONS. LA SORTIE HAUTE
TENSION DES PANNEAUX PHOTOVOLTAÏQUES PEUT PROVOQUER DES
CHOCS OU DES BLESSURES. COUVREZ LES PANNEAUX PHOTOVOLTAÏQUES
DU SOLEIL AVANT D'INSTALLER LE CÂBLAGE SOLAIRE.
The controller can accept 12V (
36 cell
) or 24V nominal (
72 cell
) Solar panel(s) with maximum
Open Circuit Voltage of up to 50V. Continuous voltage > 50V will damage the input section of
the controller.
3.4.4 Step 4: Battery Temperature Sensing and Compensation
3.4.4.1 Lead Acid Batteries have a Negative “Temperature Coefficient” i.e. the battery charging /
discharging voltages will (i) rise due to fall in electrolyte temperature resulting in under charging
if charger voltage is not compensated and (ii) fall due to rise in electrolyte temperature resulting