6 | SAMLEX AMERICA INC.
2.4 LAYOUT
1
2
3
4
5A
5B
6A
6B
7A
7B
5A
5B
6A
6B
7A
7B
9
8
LEGEND FOR FIG 2.1
Item No. Description
Item No. Description
1
Solar Panel Status LED
6A
Battery Terminal (+)
2
Battery Status LED
6B
Battery Terminal (–)
3
Load Status LED
7A
Load Terminal (+)
4
Load On/Off Button
Also used for clearing load size
overload and short circuit faults.
7B
Load Terminal (–)
5A
Solar Panel Input Terminal (+)
8
(
See NOTE 1
)
Connector for optional Remote Battery
Temperature Sensor Model "MSK-TS"
5B
Solar Panel Input Terminal (–)
9
RS-485 Communication Port
(NOT USED)
NOTES:
1. If the Remote Battery Temperature Sensor is short-circuited or damaged, the control-
ler will charge or discharge at the default temperature setting of 25°C.
2. All terminal can accept conductor size up to AWG#8 / 10mm
2
SECTION 2 |
General Information, Features
& Layout
Fig 2.1: Layout of Charge Controller MSK-20A