8 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 9
APPENDIX A
SECtION 3 |
Operation
STANDBY
BATTERY XX.XXXV
POWER SAVING
BATTERY XX.XXXV
INVERTING
OUTPUT
120.00V
CHARGING
GRID
120.00V
N-CC
Fig 3.1 eVo-RC Mode Screens
3.6.1 Charging Mode Screens explanations
Please refer to 19 Screens shown against Screens 1 to 19 under Group 3: "CHARGING
MODE" at Fig 3.2. The 1
st
line of the Display Screen for Charging Mode shows CHARGING on
the left and abbreviated information format "Charging Mode - Charging Stage" on the right
corner. The following abbreviations have been used:
Abbreviation
(Group 3 Screens)
normal (n), 3 Stage Charging:
Bulk, Absorption, Float
equalization (e), 4-Stage Charging:
Bulk, Absorption, equalization, Float
N-CC
Constant Current (CC), Bulk Stage
–
N-CV
Constant Voltage (CV), Absorption Stage –
E-CC
–
Constant Current (CC), Bulk Stage
E-CVA
–
Constant Voltage Absorption (CVA) Stage
E-CVE
–
Constant Voltage Equalization (CVE) Stage
FLOAT
Float Stage
Float Stage
For example, in Fig 3.2, the 1
st
line of information under Column 4 (Group 3) "Charging" shows
"N-CC" in the right corner. This means that the unit is in Normal (N), 3-Stage Charging Mode
and is in Constant Current (CC) Bulk Stage.
3.6.2 overall operating Mode Display Screen Menu Map
Overall Operating Mode Display Screen Menu Map is shown at Fig 3.2. Any screen within the
Menu Map can be identified by 2 co-ordinates: "Operating Mode Group No." (Column) and
"Screen No." (Row).
Содержание EVO-2212E
Страница 139: ...SAMLEX AMERICA INC 49 APPENDIX A Notes ...