4
SPECIFICATIONS
14
NOTES
1. * The current ratings of the fuses are less than the ampacity (maximum current carrying capacity) of the
cables used based on NEC Table 310.17 for free air.
2. For the purposes of the calculation of the voltage drop based on the resistance per unit length, the
length of the cable has been taken as twice the distance between the battery and the inverter to include
the overall length of the Positive and Negative cables e.g. if the distance between the battery and the
inverter is taken as 3 ft, the length of the cable has been taken as 6 ft for calculation purposes.
3. Specifi cations are liable to change without notice.
Model
DC-1000-KIT
DC-2000-KIT
DC-2500-KIT
DC-3500-KIT
Cable Gauge
AWG 4
AWG 2
AWG 2/0
AWG 4/0
Cable Length
10 feet
10 feet
10 feet
10 feet
Voltage drop
12 V system
3 ft length
0.8 %
2.5 %
1.2 %
1.0 %
6 ft length
1.6 %
5.1 %
2.3 %
2.0 %
10 ft length
2.7 %
8.4 %
3.9 %
3.3 %
24 V system
3 ft length
0.4 %
1.3 %
0.6 %
0.5 %
6 ft length
0.8 %
2.5 %
1.2 %
1.0 %
10 ft length
1.3 %
4.2 %
1.9 %
1.7 %
Fuse Size
100 Amp*
200 Amp*
300 Amp*
400 Amp*
Included hardware
6 Nos. 11.5”
Black Tie Wraps
6 Nos. 1/2”
Cable clamps
6 Nos. #8 x ¾”
Pan head screws
6 Nos. 11.5”
Black Tie Wraps
6 Nos. 1/2”
Cable clamps
6 Nos. #8 x ¾”
Pan head screws
6 Nos. 11.5”
Black Tie Wraps
6 Nos. 3/4”
Cable clamps
6 Nos. #8 x ¾”
Pan head screws
6 Nos. 11.5”
Black Tie Wraps
6 Nos. 1”
Cable clamps
6 Nos. #8 x ¾”
Pan head screws
Inverters
12 Volt
600-1000 Watt
24 Volt
600-2000 Watt
12 Volt
1000-2000 Watt
24 Volt
2000-3000 Watt
12 Volt
2000-2500 Watt
24 Volt
3000-4000 Watt
12 Volt
2500-3500 Watt
24 Volt
4000-6000 Watt