SPECIFICATIONS
PARAMETER
SEC-2440E
Nominal Input Voltage
230 VAC /50-60 Hz
(207 to 253 VAC)
Input Current
At 230 VAC input
8.7A
Output Voltage, VDC
Absorption / Boost, “Uo”*
29.6 V/28.8 V +/-0.05 V
Float / Maintenance, “U”*
27.6 V +/-0.05 V
Maximum Bulk Charging Current, I
Normal operation
40A
Half Power Mode
20 A+/-1 A
5A +/-0.5A
4 A+/-0.5 A
4 Hours or 8 Hours
(Switch selectable)
Yes. With sensor TF-500
Yes. Model 900-RC
By fan
Threshold of Current for Change Over
From Float “U” to Boost “Uo”
From Boost “Uo” to Float “U”
Duration for Absorption or
Boost Stage, Uo
Temperature Compensation
(Optional)
Wired Remote Panel
(Optional)
Cooling
Protections
overload
yes
Short Circuit
yes
Reverse polarity
yes
Thermal overload
yes
Output Banks
2
Output Connector
Tubular hole (dia 8 mm) with set screw
Operating Temperature Range
0ºC to 40ºC
Input Power Cord
(Attached)
2 Pin European schuko
Fuses
AC Input Side (6 mm x 30 mm; Slow Blow Type)
For 230 VAC input
10 A /250 V
DC Output Side (Automotive Blade Type, e.g.
Bussmann “ATC”)
In parallel
32 V, 15 A x 3pcs.
Dimensions (L x W x H), mm
382 x 230 x 108
Weight
5.5Kg