H22
www.samon.nl - [email protected]
V2-2016-ENG
20
11.
Troubleshooting
General troubleshooting diagram
Defect:
Cause:
Remedy:
Hydraulic oil temperature too
high
Low oil level
Check for leaks and top up
Speed of PTO shaft too high
Check the speed
Working pressure too high
Check the working pressure
Hydraulic oil level low
Leakage in system
Find leak and repair
Virtually no product is picked up
and product is left behind by the
machine
Intake too high
Adjust height of intake to 1 cm
under the soil
No power supply to remote
control
Fuse has blown
Replace fuse in main cabinet
Plug defective
Check plug and replace if
necessary
A specific function is unavailable
(Check whether the LED indicator
on the magnetic coil lights on
operating the function)
Relay defective
(LED indicator does not light)
Replace relay
Magnetic coil defective
(LED indicator does light)
Replace magnetic coil
Conveyor belt does not turn
Conveyor belt protection sensor
does not detect frame
Fold out the conveyor belt
completely and check whether
the sensor's LED indicator lights:
adjust sensor if necessary.
Conveyor belt protection sensor
defective
Check whether LED lights on
detection. Replace if the LED does
not light
Содержание SU1L
Страница 19: ...H17 www samon nl info samon nl V2 2016 ENG 20 9 Technical diagrams 9 1 Hydraulic diagram of hydraulic motors...
Страница 20: ...H18 www samon nl info samon nl V2 2016 ENG 20 9 2 Hydraulic diagram of hydraulic cylinders...
Страница 21: ...H19 www samon nl info samon nl V2 2016 ENG 20 9 3 Electric diagram for remote control...
Страница 22: ...H20 www samon nl info samon nl V2 2016 ENG 20 9 4 Electric diagram for main cabinet...
Страница 26: ...Spare Parts List...