Each type of operation should be avoided/suspended in stormy 
weather in place or imminent.
Pursuant to art. 29 of the Lgs. D. 81/08, the employer is 
responsible to prepare appropriate risk assessment in this regard. 
It is considered useful to provide in each case the following 
minimum safety information:
-  Each object with an elevation predominant compared with 

the surrounding area has a greater chance of being struck by 
lightning; so the use of the “machine” near or under the 
shelter of trees, towers or pylons must be considered at risk 
and, when placed above the vehicle floor, the container can 
represent itself the subject of predominant elevation relative 
to the surrounding area.

-  Not necessarily the risk of electrocution is due to the fact that 

container’s direct target of lightning. The mere proximity to 
an exposed structure constitutes danger since the current of 
the lightning, after hitting its target, is dispersed in the soil, so 
if you are in proximity to the hit structure and you are in 
contact with the ground you may come in contact with the 
leakage current and be damaged.

During transport, the power line derived from vehicle 
battery must be disconnected

It is absolutely forbidden to connect/disconnect the power 
cables to/from vehicle battery under load

!

SAFETY INSTRUCTIONS

DO NOT USE IN PLACES WHERE THERE MAY BE THE DANGER OF THE FORMATION OF EXPLOSIVE ATMOSPHERES (EN 
60079–10)

At the end of the transfer switch the electric pump off within max.2 minutes, and discharge the residual pressure acting on the gun 
for a short residual delivery. 

Store your gun and hose only after verifying the absence of drips.

During transport, the power line must be disconnected and the shut–off valve closed.

For transportation, fasten the tank with belts to prevent any movement on the loading platform.

Avoid contact of the battery terminals, although unconnected, with the product since it is corrosive.

In addition to those already given in several previous chapters, we remind the user the following important requirements, where non
– compliance may result in extremely serious consequences:

Содержание 560312

Страница 1: ...el 34 985 381 488 www samoaindustrial com 2018_06_13 16 00 Part No C d 560 312 560 313 309 201 560 311 POLYETHYLENE TANKS FOR THE TRANSPORT OF ADBLUE DEF UREA 2 TANQUES DE POLIETILENO PARA EL TRANSPOR...

Страница 2: ...nalties even serious ones by the competent authority To the knowledge of the technical aspects that SAMOA intended to highlight with this manual user will still have to match the utmost caution in the...

Страница 3: ...for rotating machines EN 60204 1 2005 AMD1 2008 CSV Safety of machinery Electrical equipment of machines Part 1 General rules UNI EN 1037 2008 Safety of machinery Prevention of unexpected start EN 12...

Страница 4: ...eparations or maintaining in quantities not higher than 450 litres for packing and fo llowing limitations of the maximum total quantities indicated in 1 1 3 6 Provisions must be adopted to avoid any c...

Страница 5: ...exceed a maximum duration of 2 minutes 1 Checking compliance of the tank with the requirements of the order the presence of the CE marking and the manufacturer s Declaration of conformity 2 Preparing...

Страница 6: ...support 8 Dispensing Gun 9 Anti spill vent cap 10 Rubber delivery pipe 11 Power cable with pliers 1 Tank body 2 Filling nozzle 2 with built in vent 3 Suction tubing 4 Electric pump with I O switch 5...

Страница 7: ...uip the tanks with the following hazard pictograms hazard pictograms of material harmful to the environment The safety of carriage must be anyway guaranteed and the prescriptions of art 164 of the Tra...

Страница 8: ...ecting the clamps to the terminals of the battery respecting the polarities red black or in case of vehicular connection page 23 verify that the circuit breaker D is active open circuit and then conne...

Страница 9: ...the current of the lightning after hitting its target is dispersed in the soil so if you are in proximity to the hit structure and you are in contact with the ground you may come in contact with the...

Страница 10: ...SAMOA establishments or in centres authorised by it as the operation is configured as reconditioning The use of non original spare parts voids the manufacturer s warranty if in course FACILITIES AND E...

Страница 11: ...inst heat RISKS FROM MANUAL HANDLING OF LOADS There remains the risk of physical workload during handling of the container this risk must be assessed and quantified by the user depending on the specif...

Страница 12: ...uloso respeto de las vigentes normativas ADR as como del Art 168 del C digo de Circulaci n y de los Art n 364 370 del relativo Reglamento de ejecuci n y disposiciones complementarias Para la comprensi...

Страница 13: ...s de protecci n proporcionados por el dise o integral de las m quinas el ctricas rotativas EN 60204 1 2005 AMD1 2008 CSV Seguridad de las m quinas Equipo el ctrico de las m quinas Parte 1 Reglas gener...

Страница 14: ...ng and fo llowing limitations of the maximum total quantities indicated in 1 1 3 6 Provisions must be adopted to avoid any content loss in normal transport conditions Transports of these companies for...

Страница 15: ...ud requisitos del pedido la presencia del marcado CE y la Declaraci n de Conformidad CE del Fabricante 2 Predisponer cualquier tipo de dotaci n o equipo suplementario requerido por la legislaci n vige...

Страница 16: ...Manguera de erogaci n de goma 11 Cable de alimentaci n con pinza 1 Cuerpo tanque 2 Tap n de llenado 2 con v lvula de purga incorporada 3 Tubo de recuperaci n 4 Electrobomba con interruptor I O 5 Cable...

Страница 17: ...os siguientes pictogramas de peligro Pictogramas de peligro materia nociva para el medio ambiente Deben estar en todo caso garantizadas las condiciones de seguridad del transporte y observados los mis...

Страница 18: ...terruptor de la electrobomba se encuentre en posici n de parada O Habilitar la l nea de alimentaci n conectando las pinzas a los bornes de la bater a respetando las polaridades rojo negro o bien s pre...

Страница 19: ...uctura afectada y se est en contacto con el suelo se puede entrar en contacto con la corriente de dispersi n y sufrir da os Durante el Transporte la l nea de alimentaci n derivada de la bater a del ve...

Страница 20: ...ales comporta la anulaci n de la garant a del fabricante si est en curso DOTACIONES Y EQUIPOS DE LA TRIPULACI N DE CABINA Efectuando el transporte en exenci n ADR no se requiere expl citamente la dota...

Страница 21: ...adores responsables de transvase y mantenimiento deben hacer uso de guantes de protecci n contra el calor RIESGO DE DESPLAZAMIENTO MANUAL DE LAS CARGAS Permanece el riesgo de carga de trabajo f sico d...

Страница 22: ...l 34 985 381 488 www samoaindustrial com 2018_06_13 16 00 kg Actual geometrical capacity l Capacidad geom trica real l B mm L mm H mm 309 201 560 311 15 111 470 500 1100 560 312 22 221 600 900 615 560...

Страница 23: ...any additional requirements provided by thevehicle manufacturer Always protect the power supply with a fuse even if already present inside the pump La instalaci n debe ser efectuada de manera profesio...

Страница 24: ...24 856 827 R 06 18 SAMOA Industrial S A Pol Ind Porceyo I 14 Camino del Font n 831 33392 Gij n Spain Tel 34 985 381 488 www samoaindustrial com 2018_06_13 16 00...

Отзывы: