5.- Heating status
6.- Actual  water temperature
7.- Estimated heating time
8.- SET timer (target)
9.- SET temperature (target)
10.- Timer status
11.- Timer countdown
12.- Temperature during the cycle
13.- Water heating kWh
14.- SET temperature symbol
15.- Actual  temperature symbol
16.- Cycle time
17.- kWh during the cycle
18.- Actual  needle probe

temperature

19.- Time passed
20.- SET needle probe temperature

12

13

14

15

16

17

18

19

20

Characteristics

Working with the needle probe

(Only with SmartVide 8)

Change

º

C/

º

F

Calibration

Connect the needle probe

to the machine.

SET set temperature

of  the needle probe

at which we want it

to warn us.

Press PLAY to save

the data.

.

Peep,  Peep...!!!

It has reached the

temperature.

Indicates the time passed.

Press any button to
view stop the beeper  sound.

Press END to finish

the cycle.

End!

SUMMARY  of  the cycle.

Press any button

for a new cycle.

1.- Machine off.

2.- Holding down the

SETbutton, switch on

the machine.

3.- Change the unit.

1.- Machine off

2.- Holding down the – and + buttons, switch

on the machine.

3.- CALIBRATION screen

4.- Adjust the value with SET and the – and +

buttons

5.- Turn off and on again.

Temperature

sensor

water

Stirrer motor

Heating

element

Overheating

cab

Lack of  water. Fill.

Power cut during the cycle.

Indicates temperature before and 

after the power cut

Note:  Call a Technical Service

Fault warning

Warnings

Reset

1.- Machine off.
2.- Push and hold “SET”, “-” and “+”, switch the machine on.
3.- Hold for 10 seconds until the machine makes a distinct sound.
4.- Turn off and on again.