8 | SAMLEX AMERICA INC.
LeD StAtUS
inDicAtoR
StAtUS oF inVeRteR
StAtUS oF USB PoRt
OFF
AC output is available
No output from USB port due to:
- Over voltage ≥6.2V
- USB section is defective
AC output is not available
No DC input, check:
- 12V Plug Adaptor (8) is firmly
connected to the 12 VDC power
source
- 15A fuse (5) is not blown
gREEN
AC output is available
USB output is available
ORANgE
AC output is not available due to operation of one
or more of the following protections:
- Over temperature
- Low DC input voltage
- High DC input voltage
USB output is available
RED
AC output is not available due to operation of one
or more of the following protections:
- Over temperature
- Low DC input voltage
- High DC input voltage
No output from USB port due to:
- Over voltage ≥6.2V
- USB section is defective
seCtIOn 3 |
Installation & Operation
cooling
- The inverter has a temperature controlled fan for cooling.
- The fan will start once the temperature of the hot spot inside the unit exceeds
70°C / 158°f. note: In cooler ambient temperature and/or at no/low loads, the hot spot
may not reach 70°C / 158°f and hence, the fan will be off.
- If the fan fails, or if adequate cool air change is not available, temperature of hot spot
will continue to rise and at ≥ 105°C / 221°f, AC output will be shut down. AC output
will be restored when the unit cools down sufficiently.
- Place the unit in a cool, well ventilated space that has adequate cool replacement
air (fig. 3.1).