General safety and Installation instructions

1.1   Operate the device safely

Warning!

Failure to observe this instruction can cause material damage, device malfunction, or danger 
of bodily injuries. 
Fundamental safety measures should be observed when using electrical equipment to avoid 
the danger of: 
– Electric shock
– Fire hazard
– Injury

 

1.2   Safety instructions when installing the device

•  Handle the batteries with care; they contain strong acids. 
•  Avoid contact with the battery fluid agent. 
•  If come in contact with battery fluid, one should rinse the affected parts of  

 

  the body or clothing with plenty of cold water and seek medical attention immediately. 
•  Be sure that the device has a firm foundation.
•   Do NOT use sharp or hard objects to clean the device; doing so may cause device    

damage.

1.3   Electrical cables

If cables have to be fed through metal walls or other walls with sharp edges, use ducts or 
wire bushings to prevent damage.

•  Lay the cables so that other people will NOT trip over them. 
•  Do NOT lay cables which are loose or bent next to electrically conductive materials. 
•  Do NOT pull the cables. 
•  Fasten the cables properly.
•  Lay the cables so that they cannot be easily damaged
•  Always use sockets that are grounded and secured by earth leakage circuit breaker.
•  Only a specialist should make the electrical connections. 
•  Do NOT lay the 115V/230V line and the 12V DC in the SAME cable duct!
•  Keep to the indicated minimum cable cross-section.

1.4   Installation on boats

•  Incorrect use or installation of the charger on boat may lead to corrosion of the boat.  
  Please allow qualified personnel to perform the installation of the charger.

Содержание WSC-1250

Страница 1: ...ENG Smart Battery Charger Smart Battery Charger Model No Smart Battery Charger Please read this manual carefully before installing and starting up this device Manual BATTERY CHARGER WSC 1250 WSC 2425...

Страница 2: ...2 Figure 1 WSC 1250 WSC 2425 Charger Front View Figure 2 WSC 1250 WSC 2425 Charger Rear View...

Страница 3: ...3 Figure 4 WSC 1250 WSC 2425 Charger Side View mm Figure 3 WSC 1250 WSC 2425 Charger Top View mm...

Страница 4: ...4 Figure 6 Cable Setup Figure 5 WSC 1250 WSC 2425 Making Connections...

Страница 5: ...5 Figure 7 Fork Figure 8 Switch...

Страница 6: ...6 Figure 9 Temperature Sensor TF 100 Figure 10 Remote Controller RC 600...

Страница 7: ...7 Figure 11 Remote Controller RC 600 Dimension mm Figure 12 Remote Controller RC 601D...

Страница 8: ...8 Figure 13 Remote Controller RC 601D Dimension mm Figure 14 Making Connections RC 601D...

Страница 9: ...9 Figure 15 Temperature Sensor Setup...

Страница 10: ...ttings 17 8 1 Charging voltage setting 17 8 2 Half power mode setting 18 8 3 Equalization setting 18 8 4 VOID setting table 18 9 Using the Charger 19 9 1 Charging characteristic 19 9 2 Using the remot...

Страница 11: ...harp or hard objects to clean the device doing so may cause device damage 1 3 Electrical cables If cables have to be fed through metal walls or other walls with sharp edges use ducts or wire bushings...

Страница 12: ...ies used onboard vehicles or boats The charger can continuously charge supply batteries or starter batteries enabling the batteries to maintain at a high capacity level The charger can be used for cha...

Страница 13: ...ure 8 Switch Page 5 4 STATUS LED 5 E Q equalization LED 6 On Off switch S2 for half power mode 7 Switch S3 for equalization on only 8 plus DC output terminal for the supply battery 9 minus DC output t...

Страница 14: ...trol at a well accessible place to ensure easy access of the charger Be careful when attaching the remote control for wiring harnesses cables and other components that are in the assembly range could...

Страница 15: ...n attaching the remote control for wiring harnesses cables and other components that are in the assembly range could be damaged in the process 5 3 2 Installation Connect this remote controller to the...

Страница 16: ...ure 5 Making Connections Page 4 Connect the plus battery pole with the connecting cable with the plus terminal at the charger see Figure 5 Making Connections Page 4 Lay the cables from the batteries t...

Страница 17: ...tch 2 I phase voltage Uo phase voltage U phase voltage OFF OFF 13 5V 27 0V 14 0V 28 0V 13 5V 27 0V OFF ON 13 5V 27 0V 14 4V 28 8V 13 5V 27 0V ON OFF 13 8V 27 6V 14 4V 28 8V 13 8V 27 6V ON ON 13 8V 27...

Страница 18: ...ting Note 1 The half power mode can be set only when equalization function is NOT activated or the charger is NOT in the power supply mode see Table 8 5 VOID Setting table for pushing switch on front...

Страница 19: ...n Others Power Supply S2 HALF POWER pushed Exit HALF POWER STATUS LED lights VOID Enter HALF POWER STATUS LED flashing VOID S3 E Q pushed VOID VOID Equalization E Q LED lights Red VOID 9 Using the Cha...

Страница 20: ...o 95 of its capacity Note The charging voltage and the period for the main charging phase Uo phase can be selected using the switch field S1 9 1 3 U phase float The STATUS LED constantly lights Green...

Страница 21: ...ON and OFF Half Power button to enter exit HALF POWER mode Equalization button to activate the function of equalization Bulk LED to indicate the charging stage of I phase Absorption LED to indicate t...

Страница 22: ...r 2 seconds to switch OFF the battery charger and 0 5 second to turn ON 9 3 Units with Temperature Sensor TF 100 A temperature sensor Figure 9 Temperature Sensor TF 100 Page 6 can be connected in orde...

Страница 23: ...and STATUS LED lights Orange and auto recover when temperature drops to 45 C 9 4 Fan Speed The fan speed is adjusted according to the load and the temperature inside the charger When the load is over...

Страница 24: ...nal Check Table E Q LED STATUS LED Status Red constantly lit I phase Orange constantly lit Uo phase Green constantly lit U phase Red constantly lit Red constantly lit I phase Equalization is activated...

Страница 25: ...nals and wait for a few minutes Then measure the voltage at the battery terminals with the multi meter 10 2 1 12V battery If the multi meter displays a voltage of 10V or less this indicates that the b...

Страница 26: ...emperature abnormal stop charging TF 100 Red flashing Red flashing Fan abnormal Red flashing Orange flashing TF 100 connected to the remote socket Red flashing Green flashing Charger overheated 100 C...

Страница 27: ...A Equalization mode 14 8V 15 5V 0 25A 29 6V 31V 0 12 5A Half power mode Silent mode 0 25A 0 12 5A Battery connection 3 Battery types Lead acid GEL AGM Li Ion Battery capacity 500Ah 250Ah Operating tem...

Страница 28: ...cil of April 20 2016 on the approximation of the laws of the Member States relating to electromagnetic compatibility and EC Low Voltage Directive For the evaluation regarding the electromagnetic inter...