background image

 

Index revision : F - November 2017

36

7012

8.2.  1-PV Block

Item

Part number

Description

Qty

Unit 

of 

sale

First 

Emer-

gency

Con-

suma-

ble

910005997

1-PV block

1

1

X

1

F6RPUK317

Fitting 1/4 BSP for 4/6 hose

2

1

X

2

F6RLUS268

Male union

2

1

X

3

X9NVCB181

Nylon screw C M 5 x 10

1

1

X

4

1507375

Microvalve, chemically inert o-rings

 

(

see RT Nr 6021

)

1

1

X

5

F6RPUQ062

Male union

2

1

X

DES04165

1

2

3

4

5

Содержание PPH 308

Страница 1: ...ovember 2017 1 7012 User manual SAMES KREMLIN SAS 13 Chemin de Malacher 38240 MEYLAN FRANCE Tel 33 0 4 76 41 60 60 www sames kremlin com PPH 308 atomizer single circuit without regulator with coil for...

Страница 2: ...s training courses in the operation and maintenance of your equipment A catalogue is available on request Choose from a wide range of courses to acquire the skills or knowledge that is required to mat...

Страница 3: ...1 5 11 O ring Seals 12 1 5 12 Ventilation 12 1 5 13 Residual pressure 12 1 5 14 Safety devices 13 1 5 15 Mechanical Collision 13 1 5 16 Ambient Temperature 13 1 5 17 Sound level 13 1 5 18 Specific mai...

Страница 4: ...ly 27 6 2 Bellcups 27 6 3 Shaping air assembly 27 6 4 Turbine 27 6 5 Injector holder 28 6 6 Injector 28 6 6 1 Disassembly 28 6 6 2 Reassembly 28 6 7 1 PV block and Manifold block 29 6 7 1 Disassembly...

Страница 5: ...user manual of the electric systems 1 1 Configuration of the certified equipment The whole of these user manuals defines the configuration of the certified equipment 1 2 Marking on the atomizer SAMES...

Страница 6: ...read and understood the user manual and all rules for installation and operation as laid out below It is the responsibility of the operators workshop manager to ensure these two points and it is also...

Страница 7: ...ent is not used and or when the equipment is broken the presence of potential energy liquid or air pres sure or electric inside the equipment Using individual protection equipment will limit the risks...

Страница 8: ...ction with the ground terminal Finally for the same reasons the spraying area must have an anti static floor such as concrete metal duckboard etc It is essential to provide sufficient ventilation in t...

Страница 9: ...int resistivity 6 M cm 1 GNM 200 control module out of the ATEX area 2 Low voltage connection 3 4 5 Supplies of paint and rinsing products peinture connected to the ground potential 6 Dump return line...

Страница 10: ...filter cartridges must be changed regularly to ensure that the air is clean PTFE tape or glue should not be used between the filter and the bearing as glue residue or pieces of PTFE may block the smal...

Страница 11: ...able so that the turbine brakes gradually if the main air supply is cut off suddenly WARNING The guarantee does not cover faults that occur if the turbine is operated with insuf ficient bearing air pr...

Страница 12: ...other without any foreign matter between them If fitting is incorrect the connection may be lost and the bell cup thrown out still spinning presenting a risk for persons and equipment 1 5 11 O ring S...

Страница 13: ...to work under room temperature between 15 C and 28 C The storage temperature will never exceed 60 C 1 5 17 Sound level The accoustic pressure level continuous equivalent weighted equals to 59 7 dBA C...

Страница 14: ...events flooding earthquake fire or similar events inadequately filtered bearing air solid particles more than 5 m in diameter inadequately filtered paint and solvent use of seals not complying with SA...

Страница 15: ...udied design and tools make maintenance easy and fast 1 Protective cover 2 Magnetic air bearing turbine type BTM see RT Nr 6350 3 Vortex shaping air assembly see RT Nr 6285 4 Bellcup see RT Nr 6285 5...

Страница 16: ...anifold contains 3 microvalves 2 4 Injector injector holder restrictor The restrictor provides a suitable pressure drop for the required flow rate The injector holder is permanently secured to the PPH...

Страница 17: ...the balance of pressure and magnetic forces The air directed onto the turbine blades controls the rotation or braking of the rotor The product is atomized by the centrifugal forces created by the rot...

Страница 18: ...he acoustic frequency signal into an electrical frequency signal for processing by the turbine speed regulation module 2 6 Shaping air This air supply circuit is used to modify the pattern size If the...

Страница 19: ...g the external bellcup Solvent passes through a pipette and uses one of the openings of the shaping air shroud to rinse the bellcup exterior 2 8 Bell cups see RT Nr 6285 The bell cup atomises all part...

Страница 20: ...Index revision F November 2017 20 7012 3 Characteristics of the PPH 308 Atomizer 3 1 Dimensions mm 719 Dia 120 179 DES03689...

Страница 21: ...bar Maximum pressure 10 bar max Viscosity 12 to 40 seconds FORD cup 4 Viscosity 12 to 45 seconds AFNOR cup 4 Resistivity 6 M cm Air pressure Microvalve pilot 6 to 10 bar max Bearing air 6 to 7 bar ma...

Страница 22: ...a compressed air sequence circuits 31 32 and 36 must be purged and dried before restarting the high voltage 4 3 Microphone air diagram N B All hoses are made of polyamide dimen sions in mm 11 Paint s...

Страница 23: ...e dimen sions in mm 4 6 Compensation air diagram 25 The compensation air prevents any contam ination of the shaping air shroud and is con trolled via a remote regulator 21 Turbine drive 7 x 10 polyure...

Страница 24: ...Index revision F November 2017 24 7012 4 7 Turbine exhaust diagram N B All hoses are made of polyamide dimen sions in mm 421 Turbine exhaust 8 x 10 421 DES03086...

Страница 25: ...ization Step 2 Switch off the high voltage power supply Step 3 Run a rinsing cycle Step 4 Switch off the shaping air Step 5 Switch off turbine rotation and wait until it has stopped completely 0 rpm S...

Страница 26: ...Removal tool 65 EC magnetic bellcup 1 1 900000803 Removal tool 50 EC magnetic bellcup 1 900000804 Removal tool 35 EC magnetic bellcup 1 Part number Description Qty Unit of sale 1303689 Removal tool fo...

Страница 27: ...block except the hoses between the 1 PV block and the manifold Remove the 4 screws securing the PPH 308 to its support Remove the UHT 155 from its sleeve WARNING Leave the grips in place on the manif...

Страница 28: ...p see RT Nr 6285 Remove the outer cover Remove the shaping air shroud Unscrew the injector Caution left thread using a 5 mm flat wrench Cleaning see 7 page 30 6 6 2 Reassembly Place the injector in th...

Страница 29: ...ll o rings are in place on the Manifold Insert the brace in the 1 PV block and screw it on the manifold Secure the brace firmly to the support by tightening the screw fully Connect the hoses linking t...

Страница 30: ...use of anti static plastic films to protect bodies and insulating covers of the atomizers These films are conductive and can short circuit the high voltage SAMES KREMLIN forbids the use of adhesives o...

Страница 31: ...g air remain under pressure to block the solvent flow between the bellcup and shaping air shroud and to prevent any blockage Clean the outer cover and the exterior bellcup using a clean rag Check that...

Страница 32: ...tool Leave to soak in solvent for one hour then clean with a clean cloth and soft brush WARNING Make sure that all surfaces are clean and free from impurities Take care particu larly of the internal a...

Страница 33: ...outer cover Step 4 Dry carrefully with compressed air insisting on the holes to eliminate the paint residues then wipe with a clean dry rag Step 5 Check the shaping air shroud clean it if necessary us...

Страница 34: ...F November 2017 34 7012 8 Spare Parts Lists 8 1 PPH 308 Internal Charge single circuit without regulator with coil Bellcup and shaping air assembly are not included DES04172 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 35: ...ective cover 1 1 4 910000295 S6 Magnetic air bearing Turbine type BTM see RT Nr 6350 1 1 X 5 X4FVSY067 Screw Chc M3x10 stainless steel 5 1 6 1520282 High voltage unit UHT 155 EEx em see RT Nr 6218 1 1...

Страница 36: ...sale First Emer gency Con suma ble 910005997 1 PV block 1 1 X 1 F6RPUK317 Fitting 1 4 BSP for 4 6 hose 2 1 X 2 F6RLUS268 Male union 2 1 X 3 X9NVCB181 Nylon screw C M 5 x 10 1 1 X 4 1507375 Microvalve...

Страница 37: ...pin shaping air 1 1 3 J3STKL078 O ring chemically inert 6 1 X 4 1507375 Microvalve chemically inert o rings see RT Nr 6021 3 1 X 910010850 Microvalve with bellow see RT Nr 6422 3 option 1 X 5 J3STKL0...

Страница 38: ...13 J2FTCF051 O ring viton 1 2 X 14 F6RPUQ062 Male union 2 1 X 15 F6RPUK317 Male union 2 1 X 16 F6RXZG081 Stainless steel grip and o ring 3 1 17 F6RXZG082 Stainless steel grip and o ring 3 1 18 F6RXZG...

Страница 39: ...Qty Sale Unit First Emer gency Con suma ble 910001130 Injector injector holder assembly 1 1 X 1 738354 Injector holder 1 1 2 X4FVSY067 Screw C M 3 x 10 stainless steel 3 1 3 J3STKL014 O ring chemicall...

Страница 40: ...640403 D 1 2 mm White 640456 D 1 5 mm 1 White 640464 D 3 0 mm 2 White Part number Injector Qty of grooves 738632 D 0 9 mm 738353 D 1 2 mm 2 738634 D 1 5 mm 3 738635 D 1 8 mm 4 Item Part number Descri...