Index revision : D - March 2018
35
7115
•
Step 3
: Clip the PTFE conductive washer.
Replace it if necessary. It is advised not to
reuse it more of 3 or 4 times, the washer
should not be able to be removed without
the use of a tool.
•
Step 4
: Check the continuity between the
conductive PTFE washer and the metal
end of the electrode. The usually measured
value is of the order of 200 to 300
Ω
but a
value up to 1000
Ω
is admissible.
•
Step 5
: Fold the electrode with the flat pliers
and cut to about 5 mm.
WARNING : The small PTFE tube must not mask
the end of the electrode, cut it if necessary. On
the other hand the metallic end can be a little
discovered (less than 1mm).
WARNING : The electrode must not be in contact
with the injector when the air cap is mounted on
the gun.
Continuity
Check