Index revision : D - March 2018
29
7115
WARNING : Prior to any maintenance operation carried out on the gun, please refer to the
health and safety instructions (
- Disconnect the control module.
- Check that the air and paint circuits are no longer pressurised.
- Dump the paint circuit.
10.2. Electro-pneumatic coupling
•
Step 1:
Unscrew the 7/10 air hose coupling nut
using a 16 flat wrench (not mandatory for
Step 3)
•
Step 2:
Disassemble the low-voltage cable
using a 3 Allen wrench, unscrew the two cap-
tive screws of the electro-pneumatic cou-
pling.
•
Step 3:
Disconnect the electro-pneumatic
coupling by pulling on it.
Step 1
Step 2
Step 3
Coupling