Index revision : D - March 2018
17
7115
4.2. Flows
4.2.1. Versions without whip (LR)
Flat spray
:
Nota: The flow rate measurements were conducted with water.The width of the impact is
measured at a distance of 25 cm (10 inches).
Hollow cone round spray
:
Note: The hollow cone only gives good results at high product pressures; we do not recommend
working below 140 bar. The best results are obtained between 160 and 200 bar.
Gauge
Flow rate (in cc/min)
Width, in
cm
at 70 bar
at 120 bar
at 200 bar
03-05
150
200
260
12
03-07
150
200
260
17
04-05
220
290
380
12
04-07
220
290
380
17
04-09
220
290
380
21
04-11
220
290
380
25
04-13
220
290
380
29
06-09
330
430
570
21
06-11
330
430
570
25
06-13
330
430
570
29
06-15
330
430
570
33
09-09
450
590
770
21
09-11
450
590
770
25
09-13
450
590
770
29
09-15
450
590
770
33
12-11
600
790
1030
25
12-13
600
790
1030
29
12-15
600
790
1030
33
14-09
720
940
1230
21
14-11
720
940
1230
25
14-13
720
940
1230
29
14-15
720
940
1230
33
14-17
720
940
1230
37
Gauge
Flow rate (in cc/min)
Impact diameter
at 250 mm
Impact diameter
at 250 mm
Dynamic air
pressure
Nanogun 120 bar
Spraying air
4 bars
Nanogun 200 bar
Spraying air
4 bars
Dynamic
product pressure
120
140
200
140
200
K20
250
260
330
100
110
K30
320
350
420
110
120
K40
400
440
540
110
120
K50
580
600
780
120
130
K60
900
1000
1200
120
130
K70
900
1000
1200
120
130