Index revision : A
39
7145
10.2.2. From Inobox to a CAN module
8 bytes of feedback are exchanged fom Inobox to a CAN module
Byte
Label
Description
Unit
Max.
0
Status 1
Status information 1(see description hereafter)
-
-
1
Status 2
Status information 2 (see description hereafter)
-
-
2
Fault 1
Fault information 1 (see description hereafter)
-
-
3
Fault 2
Fault information 2 (see description hereafter)
-
-
4
HV ouput current
µA
110
5
HV ouput voltage
kV
100
6
Injection or Blowing flow
rates
Bit 8 =0 Injection on 7bits in l/min
Bit 8=1 blowing on 7 bits in dl/min
L/min or
dl/min
110/90
7
Dilution or fluidisation flow
rates
Bit 8=1 Fluidisation on 7 bits in L/min if big valve
or dL/min if small valve
L/min or
dl/min
70
Byte 0
Statut 1
Status information 1
7
Initialisation
Software in initialization step
6
5
High voltage ON
High Voltage is effectively active
4
HV request OK
The HV request is taken into account by the Inobox
3
External cleaning
External cleaning is requested (1 on the input), it will be taken into
account if the PLC has not requested cleaning control
2
External HV trigger
External HV trigger is requested (1 on the input), it will be taken
into account if the PLC has not requested HV control
1
Cleaning request OK
The cleaning start request is taken into account by theInobox
0
Cleaning in pogress
A cleaning is in progress (the air controls are at maximum, there is
no controlled HV)
Byte 1
Statut 2
Status information 2
7
Manual spray gun
A manual spray gun is connected (if set to 1)
6
Fault with 24V cutoff
Resettable fault only after a 24V shutdown
5
Configured communica-
tion module
The communication module is configured
4
Fault
A fault is present
3
Wireless control - reserved
Control mode by wireless - reserved
2
CAN Control
Control mode by the CAN communication
1
USB Control - reserved
Control mode by the USB software - reserved
0
PLC Control
Control mode by the PLC (via the communication module)