Index revision : A
35
7145
Pictogramme
associé
N° et Libellé du défaut
Description
29 - HVU link fault
The barrel is not or badly connected to the module.
Resettable by Acknowledging Fault
30 - Internal BUS fault
Internal bus overvoltage (detected by hardware or
software)
Resettable by fault acknowledgment
32 - Injection fault
An injection control is activated without pressure
feedback. Resettable by Fault Acknowledgement
33 - Dilution fault
A dilution control is activated without pressure
feedback. Resettable by Fault Acknowledgement
34 - Blowing fault
A blowing control is activated without current feed-
back from the activated valve. Resettable by Fault
Acknowledgement
35 - Fluidisation fault
A fluidisation control is activated without current
feedback from the activated valve. Resettable by
Fault Acknowledgement
37 - Spray gun or projector
connector fault
No projector or spray gun connected
Resettable by Acknowledgment Fault, unless the
connected projector or spray gun is different from
that at start-up