Index revision : A
38
7145
Byte 0
CAN Command
7
ON/OFF trigger
HV trigger start (set to 1)/ stop (set to 0) request.
The request is only taken into account if the CAN control is
enabled by the Inobox and if the HV pilot is requested.
If a manual spray gun is connected, this request must be set to 1 to
authorize control of the HV or acknowledgment of a fault by the
spray gun trigger
6
Cleaning ON/OFF
Cleaning start (set to 1) / stop (set to 0) request.
The request is only taken into account if the CAN control is
enabled by the Inobox and if the cleaning pilot is requested
5
Fault acknowledgement
Request for acknowledgement of ressettable faults
The request is only taken into account on rising edge if the CAN
control is validated by the Inobox and if there is no longer a
request for trigger operation or cleaning (by the CAN or external)
4
Local setpoint prohibited
If a manual spray gun is connected, it is possible to prohibit the
local injection setpoint (set to 1)
Otherwise the operator can modify the injection setpoint by simul-
taneously pressing the trigger and activating the + or - keys.
3
Cleaning control request
The CAN asks to control the cleaning (active if set to 1), to 0 wired
control.
The request is only taken into account if the CAN control is
enabled by the Inobox
2
HV control request
If an automatic projector is connected, request for high voltage
control via the CAN (if set to 1).
The request is only taken into account if the CAN control is
enabled by the Inobox.
If a manual spray gun is connected, this request must be set to 1 to
authorize control of the HV or acknowledgment of a fault by the
spray gun trigger
1
0
CAN control request
The CAN asks to control the Inobox (active if set to 1)